  • Page 1 Downdraft Vent systems 36" Wide Models: ZVB36 30" Wide Models: ZVB30 Monogram_ _ We bring go_Jflthings to life,...
  • Page 2 Safetv Information BEFORE YOU BEGIN WARNING Read/these instructions completely To reduce the risk of fire, electric and carefully. shock, or injury to persons, observe JMPORTANT - Save these instructions following. A. Use this unit only in the manner intended bythe local inspector's use.
  • Page 3: Table Of Contents

    MODELS AVAILABLE PRODUCT DIMENSIONS 30" Models 30" 28-1/2" 36" Models 36" 34" ZVB36 36" Wide Downdraff Vent in white, black and stainless steel 27" ZVB30 30" Wide Downdraff Vent in white, black and stainless steel : 8-1/2 ACCESSORIES 7-1/2" I 24/4"...
  • Page 4: Advance Planning

    Design mnformation ADVANCE PLANNING Before begin, must: Remote Switch 1. Review countertop dimension illustrations to be The downdraft vent has a separate raise/lower switch. sure you will have enough flat countertop surface. Plan to install the switch in a convenient location 2.
  • Page 5 Design mnformation Clearances Ductwork • The downdraft system with blower, motor and duct Prepare ductwork to vent to the outdoors. work will occupythe cabinet below the countertop • Use the shortest and straightest duct run possible. and cooktop. , The maximum permissible length for duct run is 150 feet.
  • Page 6: Installation Preparation Zeu769 Combination Cutout

    mnstaJiation Preparation CUTOUTS AND CLEARANCES * Identify the cutout illustration for the cooktop model * Measure carefully when cutting the countertop. you are installing. Make sure sides of the opening are parallel and rear * Draw Bines on the countertop to follow as a cutting and front cuts are exactly perpendicuBr to sides.
  • Page 7: Zeu30R Combination Cutout

    Installation Preparation ZEU30R DIGITAL COOKTOPS WITH 30" VENT 2-1/2" to Cutout 1-3/4" Min. Cool<topCutout to Rear Vertical Combustible Surface 29-7/8" (SS) Thick Support Rail 23-1/2" (SS) 22-1/4" 23-3/8" (B,W) 28-1/2" Cutout Total Flat Cool<top Area Cutout Surface Depth Required 5/8" Cool<topOverlap at Center _ (1-1/8"...
  • Page 8: Zgu36Gg Combination Cutout

    mnstaliation Preparation ZGU36GG GAS COOKTOPS WITH 36" VENT 2-1/2" to 2-1/4" Min. Cool<topCutout to Rear Cutout 1-7/8" Vertical Combustible Surface 3/4" Thick 36" ,-1_1/4" O_erlap Support _____f_q/8' G ap Rail 21-3/4" 23-1/2" (SS) 23-3/8" ( B,W) Cutout 34" Cool<topand Vent Cutout Total Fiat Depth Surface...
  • Page 9: Clearances

    Installation Preparation CAUTION Wall coverings, countertops and cabinets shouN Gas- 6" to 11-9/16" wkhstand 200° heat generated by any cooktop. Electric- 2" Clearance to Side Walls PRUDENCE Les rev_tements muraux, Jes dessus de comptoir et les armoires de cuisine doivent r_sister a Ja temp6rature de 95 -oC (200 -°F)cr_6e par toute table de cuisson.
  • Page 10: Power Supply

    mnstaliation Preparation POWER SUPPLY Do Not Locate Gasor Electrical Connections Within Shaded Area FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning instaflation. Outlet 12" Above Do not use an extension cord or Cabinet Floor adapter plug with this appliance. Follow National for 36"...
  • Page 11: Venting Options

    JnstaJJation Preparation LoosenScrews VENTING OPTIONS toAdjust 3-1/2" to Left or Right _ The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to the left or right side. The blower outlet is sized for 3ol/4" x 10" and can be transitioned to 6"...
  • Page 12: Ductwork

    Total Duct Run standards such as equivalent. Equivalent Jengtb of duct pieces are based those published by on actual tests conducted by GE Evaluation Engineer- NFPA and ASHRAE. ing and reflect requirements for good veering performance with any downdraft cooktop.
  • Page 13: Installation Instructions Step 1, Install Downdraft Vent

    Instamiation Instructions [STEP 21 iNSTALL THE DUCTWORK [STEP llJNSTALL DOWNDRAFT The downdraft blower system is designed for use with 3-1/4" x 10"ductwork. It can be transitioned to 6" Place the downdraft vent into the countertop cutout, round. against the back side. * Ductwork MUST be vented tothe outside - never in a crawl space, attic or other enclosed space.
  • Page 14: Step 3, Install Raise/Lower Switch

    mnstamiation mnstructions [STEP 31 iNSTALL RAiSE/LOWER SWITCH AVERTiSSEMENT WARNING: Disconnect electrical power from unit before II faut d_brancher Valimentation _lectrique de beginnhlg switch installation. Failure to do so could Vappareil avant de commencer I'installation de result in personal injury or damage to the electrical Hnterrupteur.
  • Page 15: Step 4, Connect Power

    Stainless Steel Magic is available at Ace, True Value, CHECK OPERATION Servistar, HWl and other leading stores. It is also available through GE Parts by calling 1-800-626-2002. Order part number WXlOX15. To raise the vent, press the RAISE/LOWER switch. The switch is installed in a separate location.
  • Page 16 Note: While performing installations described in this book, safety glasses or goggles should be worn, t4_ M};_zog'l-_l _/o_'_l _n, _'_i_ },_J_l _*_, _'_fl Webringgoodthingsto life, GE Consumer Producls Pub.No.49-80185 GenerM Llecm; Company Louisvifle , KY40225 Dwg.No. 164D4290P341 @ 2fir)3 Gefleral ElecTril; Conlpaf?y...