Pre-Installation; Preparing The Opening - GE CP350 Installation Instructions Manual

30" electric
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
PRE-INSTALLATION
CHECKLIST
WARN ING - The electrical power to
the cooktop
supply line must be shut offwhile
connections
are being made. Failure to do so
could result in serious injury or death.
r_
When preparing
cooktop
opening, make sure
the inside of the cabinet and the cooktop
do
not interfere with each other. (See section on
preparing the opening.)
r_
Remove packaging
materials
and literature
package from the cooktop before beginning
installation.
Cooktop
Fa
ra
Remove Installation
Instructions
from literature
pack and read them
carefully
before you begin.
Be sure to place all
literature,
Owner's Manual,
Installations,
etc. in a safe
place for future reference.
_SYINSTALL_ON O r YOUR N _
30" OOOKT_
_%:m.;%':_
g',51:12,_'2;':::'
Make sure you have all the tools and materials
you need before starting the installation
of the
cooktop.
Your home must provide the adequate
electrical
service needed to safely and
properly use your cooktop. (Refer to section on
electrical
requirements.)
When installing your cooktop in your home,
make sure all local codes and ordinances
are
followed exactly as stated.
Make sure the wall coverings, countertop
and
cabinets around the cooktop
can withstand
heat (up to 200°F) generated
by the cooktop.
PREPARING THE OPENING
r_
The following
MINIMUM clearance
dimensions
must be maintained.
13"MAX, Depth of unprotected
overhead cabinets
1-1/2"
HIN.
Clearance
from
cutout
to side wall
on the right
of the
unit
30" MIN.
Clearance from
15" MIN. Height
countertop to
countertop to
unprotected
nearest cabinet on
overhead
either side of unit
surface
2" IV]IN, Clearance
from cutout
to side
wall on the left of
the unit
If a 30" clearance
between the cooking surface and
overhead combustible
materials
or metal cabinets
cannot be maintained,
a minimum
clearance of 24"
is required and the underside
of the cabinets
above
the cooktop
must be protected
with not less than
1/4" insulating
millboard
covered with sheet metal
not less than 0.0122" thick.
r_
OVERALL COOKTOP DIMENSIONS
29-3/4"
..._I_'._
21-5/8"
(21-1/2"
SS)
129-_J8'
_SA
_,I_ __
_LI
_-=J_,
Front
L//
Cnn_nn
_
4-3/16"
Rear
___
_.....
_"
__"_
at the conduit
L---...m____1-_...,.l
, location
"I*'1
6-1/4"
Rear
on Model PP945
19-i/4"
q_._.,-,_
& PP950
r_
VERTICAL CLEARANCE
Allow 5" minimum
8-1/4"
vertical clearance
from the cooktop
bottom (or 8-1/4"
minimum
depth from
the countertop)
to any
combustible
surfaces,
such as a cabinet
drawer.