Location Requirements - Admiral AED4675YQ1 Installation Instructions Manual

29" wide models
Table of Contents

Advertisement

Location Requirements
Explosion Hazard
Keep flarnnrnab(e materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 rnrn) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[]
A location allowing for proper exhaust installation.
See "Venting Requirements."
[]
A separate 30 amp circuit.
[]
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
[]
A sturdy floor to support the total weight (dryer and load)
of 200 Ibs. (90.7 kg). The combined weight of a companion
appliance should also be considered.
[]
Level floor with maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
Minimum spacing for recessed
area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
[]
Additional
spacing should be considered for ease of
installation and servicing.
[]
Additional
clearances might be required for wall, door, and
floor moldings.
[]
Additional
spacing of 1" (25 mm) on all sides of the dryer
is recommended
to reduce noise transfer.
[]
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
Companion appliance spacing should also be considered.
[]
Minimum
Required
Spacing
_14"max,' -
_]
48in'_
h_ I(_ mm 310crn)_.
24 in?* -
-...
.--__ (155 cm) _
_f
3 I1.
i-#0 ram)
_76mm)
1"_ _ 29"_ _ 1" _h"*l< 27_"_151/2"I
<-
(25ram)
( 737mm) (25mm) (25mm)(705mrn}
(140mm)
A
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional
spacing
recommended
C
Mobile
home
= Additional
installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
[]
[]
Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such
as a nearby window) should be at least twice as large
as the dryer exhaust opening.
.... 223,,,,
i' i
433/8i
..............
_
{1102 ram}
....... 29"
(737ram)
(737rnm}
A
B
A. Wideopening side-swing door
B. Wideopening hamper door
*Most installations require a minimum 51/2 '' (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."