C
Place hooked end of neutral wire (white or center) (C) of direct
wire cable under center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
7, Connect
remaining
wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with hold-
down screw. Now, go to Venting Requirements.
Optional
3-wire Connection
You must
verify with a qualified
electrician
that
this
grounding
method
is acceptable
before
connecting.
ground
wire and neutral wire
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
and neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
4, Connect
external
ground
wire
G
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to Venting
Requirements.