Admiral AED4675YQ0 Installation Instructions Manual page 9

29" wide models
Table of Contents

Advertisement

Direct Wire Connection
Direct wire strain relief
1. Attach
direct
wire strain
relief
A
B
C
Unscrew the removable conduit connector (A) and any screws
from a 3/4" (19 mm) UL listed strain relief (UL marking on strain
relief). Put the threaded section of the strain relief through the
hole (B) below the terminal block opening. Reaching inside
the terminal block opening, screw the removable conduit
connector
onto the strain relief threads (C).
to strain
relief
Put direct wire cable through the strain relief. The strain relief
should have a tight fit with the dryer cabinet and be in a
horizontal position. Tighten strain relief screws.
For 3-wire Direct Wire Connection,
see page 10.
For 4 wire Direct Wire Connection,
continue to step 3 on
this page.
4owire Direct
Wire Connection
IMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit 3-wire
connections.
3.
Prepare your 4-wire
cable for
direct
connection
(127
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 11/2'' (38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
4, Connect
wires to terminal
block
To connect wires to terminal block, place hooked end of
wire under terminal block screw, facing to the right, squeeze
hooked end together and tighten screw.
ground
wire and neutral
wire
Remove center, silver-colored
terminal block screw (B).
Remove neutral ground wire (E) from external ground
conductor
screw (A).