Admiral AED4675YQ0 Installation Instructions Manual page 10

29" wide models
Table of Contents

Advertisement

and neutral
wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
3owire Direct
Wire Connection
Use where local codes permit connecting
cabinet-ground
conductor
to neutral wire.
3.
Prepare your 3-wire cable for
direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 31/2'' (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
4, Connect
wires to terminal
block
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
To connect wires to terminal block, place hooked end of wire
under terminal block screw, facing to the right, squeeze
hooked end together and tighten screw.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
Venting Requirements.
Remove center, silver-colored
terminal block screw (B).
10