Download Print this page

Jenn-Air JGC8430 Installation Manual page 2

Sealed gas cooktop
Hide thumbs Also See for JGC8430:

Advertisement

Available languages

Available languages

Location Of Your Jenn-Air
Appliance
Locate this appliance away from combustible materials
such as window curtains and combustible wall
decorations.
Minimum horizontal clearance between the edge of the
appliance and combustible construction extending from
the cooking surface to 18" (45.72 cm) above the cooking
surface is:
3/4" (1.91 cm) at rear
8" (20.32 cm) at sides
(Dimensions
apply to both 30" & 36" wide models).
?
/I
/
//
i
1!
45.72 crn
1.91 cm
8 ,_
FIGURE1
20.32 crn
WARNING
THIS PRODUCTSHOULDNOT
BE INSTALLED BELOWA
VENTILATION TYPE HOOD
SYSTEMTHATDIRECTSAIR
IN A DOWNWARD DIRECTION.
ART
@
9215-252
(SEE FIGURE)
THESESYSTEMSMAYCAUSE
IGNITIONAND COMBUSTION
PROBLEMS WITH THE GAS
BURNERSRESULTING IN
PERSONALINJURYAND MAY
AFFECTTHE COOKING
PERFORMANCE OF THE UNIT.
NOTE:THE FIGUREMAYNOTACCURATELY REPRESENT YOUR
RANGEORCOOKTOP;HOWEVER, T HISWARNING APPLIESTO
ALL GAS COOKINGPRODUCTS.
Preparation
Of Countertop
The countertop cutout must be prepared according to the
illustration on page 1 of these instructions.
CAUTION:
Cutout dimensions are critical. Dimensions
must be measured and cut accurately to within + 1/16"
(. 159 cm) to ensure proper fit.
Important
Preparation
Suggestions
1. Chamfer all exposed edges of decorative laminate to
prevent damage from chipping.
2. Radius corners of cutout and file to insure smooth
edges and prevent corner cracking, Recommend
1/4" or 3/8" diameter drill in each corner,
3. Rough edges, inside corners which have not been
rounded and forced fits can contribute to cracking of
the countertop laminate.
4. Countertop must be supported within 3" (7.62 cm) of
cutout.
Installing
Cabinetry
Over Your
Jenn-Air
Cooktop
A = 30" (76.2 cm) minimum
vertical clearance
between cooking surface
and construction above
the appliance. This
clearance may be
reduced to not less than
24 inches (60.96 cm) by
protecting the underside
of the combustible
material or metal cabinet
above the cooking
surface with not less than
1/4 inch (.635 cm)
insulating millboard
covered with sheet metal
not less than 0.0122 inch
thick.
A
FIGURE2
B = 13" (33.02 cm) maximum depth of cabinets installed
above cooktop.
Avoid use of cabinets above cooktop for storage space to
eliminate associated potential hazards such as reaching
over open flames.
Required
Adjustments
At Time Of Installation
The installation of this appliance must conform with Ioca codes, or in the absence of local codes, with the latest edition
)fthe National Fue Gas Code ANSI Z223.1 USA or current CAN/CGA-B149
INSTALLATION
CODE.
[]
This appliance was manufactured for use with Natural Gas. If LP gas is the fuel of choice, follow the conversion to
LP procedure found in the installation instructions.
[]
Test all external connections for gas leaks. Never test for gas leaks with an open flame.
[]
Test all electrical connections.

Advertisement

loading

This manual is also suitable for:

Jgc8536