CONNECTING
THE RANGE
FIGURE 4
3-Wire Service Cord or Conduit
Installation
1. Insure that the copper ground strap IS CONNECTED
between the middle post of the main terminal
connection block and the range chassis.
2. If bare copper or aluminum wiring is used, attach
adapter lugs as shown in figure 4. (See Bare Wire
Connection), Torque specifications are shown below.
3, The middle wire of the service cord or ground lead of
3-wire conduit MUST connect to the neutral (middle)
post of the main terminal block. The other two wires of
the service cord or conduit connect to the outside
posts of the main terminal connection block. Polarity is
unimportant. If using bare wire, attach wire to
appropriate lug as shown. Torque specifications are
shown below.
4. An appropriate strain relief for service cord or conduit
MUST be attached to the conduit plate.
ACCEPTABLE
- 3 WIRE
PLUG
INSTALLATION
WHITE
BLACK
RED
MAIN TERMINAL
CONNECTION BLOCK
NtDDLE WIRE OF
SERVICE CORD
OR CONDUIT
GROUNDING STRAP
CONNECTED AT
FACTORY
STRAIN
CONDUIT
RELIEF
PLATE
FLOOR
'
FOR USE WITH CONDUIT.
RECEPTACLE
MOUNTED FLUSH
TO WALL
ADAPTER
LUGSLOCATED
IN LITERATUREKIT
RED
BLACK
WHITE
BARE
WIRE
TOROU_
SP[CIFICATION£
LUGATTACHED T O TERHINALDLOCK - 20 IN.L6
10.14
20 IN-L6
O
25 IN-LB
4.5
3S Ii-Lfi
ALTERNATIVE" INSTALLATION
REMOVE BRACKET.FLIP
& RE-ATTACHWITH SHALL
HOLEVISIBLE,
OUTLET RECEPTACLE TO BE ROTATE
IN ACCORDANCE
WITH LOCAL CODES
FIGURE 4
-6-