Terminal Information; Dsub-9P (Rs-232); Dsub-15P (Ptz / Aux / Alarm / Sensor) - Monacor DMR – 450 User Manual

4-channel digital multiplex recorder
Table of Contents

Advertisement

5.2 Terminal Information

5.2.1

DSUB-9P (RS-232)

1
6
No
Name
2
RXD
3
TXD
5
GND
5.2.2

DSUB-15P (PTZ / AUX / ALARM / SENSOR)

1
9
No
Name
1
RS-485+
2
RS-485-
3
AUX1
4
AUX2
5
AUX3
6
AUX4
7
AUX5
8
GND
* Abbreviation
RSI
Record Start In
RI
Alarm Reset In
RONOFFI
Record On Off In
ARO
Alarm Record Out
5
9
Description
Receive Data
Transmit Data
Signal Ground
8
15
Description
RS-485 Transmit Data +
RS-485 Transmit Data -
Auxiliary In Port
(RSI, ARI, RONOFFI)*
Auxiliary Out Port
(ARO, RSTO, ERRO,
DFO, RSO)*
Signal Ground
No
Name
9
Alarm Out
10
Alarm Out
11
Alarm Out
12
Sensor1
13
Sensor2
14
Sensor3
15
Sensor4
RSTO
Record Start Out
ERRO
Error Out
DFO
Disk Full Out
RSO
Record Status Out
116
Description
Alarm Out (NO)
Alarm Out (COM)
Alarm Out (NC)
NO/NC

Advertisement

Table of Contents
loading

Table of Contents