MESSAGE DISPLAYED
Press Start to Find
Brewer Home
Printer Error
Printer Offline
SPI Eeprom Error
Tank Not Heating Error
Temperature Probe
Error
Verify Powder 1 Level
Verify Powder 2 Level
Verify Product Level 1
Verify Product Level 2
Verify Waste Bin Level
CAUSE
The brewer is not in the
home (starting) position.
The printer wiring is not
connected.
The printer is connected
but it is offline.
No communication to the
options board.
The hot water tank is not
heating.
The electronic
temperature probe is not
working properly.
Powder 1 dispenser is
low and required refilling.
Powder 2 dispenser is
low and required refilling.
Coffee 1 dispenser is low
and required refilling.
Coffee 2 dispenser is low
and required refilling.
Waste bin may be full.
August 8, 2013
Eccellenza Express – Operating Manual
POSSIBLE REMEDIES
Press "
" (the
START
TEXT BOX
top of the screen) to cycle the brewer.
If the brewer cannot detect the home
position, check the brewer home switch
& wiring, the brewer motor, and the
brewer.
Connect the wiring to the printer
module.
Press the ON/OFF line button
(power) on the printer.
Check the wiring to the board.
Replace the options board.
Check the 15 amp fuse.
Reset the thermal cut-off switch.
Verify wiring to heater element.
Check heater element.
Replace the temperature probe.
Refill the dispenser for powder 1.
Reset the "Refill" message for the
Powder 1 dispenser.
Refill the dispenser for powder 2.
Reset the "Refill" message for the
Powder 2 dispenser.
Refill the dispenser for coffee 1.
Reset the "Refill" message for the
Coffee 1 dispenser.
Refill the dispenser for coffee 2.
Reset the "Refill" message for the
Coffee 2 dispenser.
Empty the contents of the waste bin.
Reset the "Waste Bin" counter.
at the