Applying Power (Side View) - N-Tron 308FX2 User Manual & Installation Manual

Industrial ethernet switches
Table of Contents

Advertisement

Applying Power (Side View)

Unscrew & Remove the DC Voltage Input Plug(s) from the side header
Install the DC Power Cables into the Plug(s) (observing polarity).
Plug the Voltage Input Plug(s) back into the side header.
Tightening torque for the terminal block power plug is 0.22 Nm/0.162 Pound Foot.
All LED‟s will flash ON Momentarily
Verify the Power LED stays ON (GREEN).
Note: Only 1 plug must be connected to power for minimal operation. For redundant power operation,
V
and V
plugs must be connected to separate DC Voltage sources. Use wire sizes 16-28 gauge. The
1
2
power cord should be limited to less than 10 meters in order to ensure optimum performance.
Recommended 24V DC Power Supplies, similar to 100VAC/240VAC:
N-Tron‟s NTPS-24-1.3, DC 24V/1.3A.
(Revised 2010-7-30)