Hanging On The Wall - Pioneer PDP-60MXE20 Technical Manual

Plasma display monitor
Hide thumbs Also See for PDP-60MXE20:
Table of Contents

Advertisement

3.4.2 Hanging on the wall

Carefully read the following imformation before attempting to hang the unit on a wall. Take note of the various limitations
specified in this section. Mount the unit so that twisting, bending, or any other warping does not exceed 4 mm.
A
50
C
Operating temperature restrictions
✩ Standard single-unit installation
Distance from wall (A)
50 mm or less
50 mm or more
✩ Requirements when used with PDP-S55-LR speaker system
When installed as a single unit, all requirements are the same as those listed above for horizontal/
vertical, left/right reverse installations. However, the figures listed above indicate the distance
between the speakers and the wall.
Note
Different temperature restrictions apply to the PDK-WM03. Refer to "4.5 Wall Mount Unit PDK-WM03" (pg. 70). For a
wall-mount installation, allow adequate space (a clearance of 300 mm or more) above, below, and to each side of the
panel.
Shaded areas
: Thermometer (temperature measurement point)
D
B
300 mm or more
300 mm or more
100 mm or more
50 mm or more
Special Instruction (Hanging on the wall)
indicate attachment points for mounting hardware.
1470
C
D
300 mm or more
50 mm or more
D
Ambient temperature
0 °C to 35 °C
0 °C to 40 °C
27