Special Installation (Hanging from wall)
3.4.2 Hanging on the wall
Carefully read the following before attempting to mount the unit on a wall, and observe the various limitations specified
below. Be sure to mount the unit so that twisting, bending or any other deformation of the unit does not exceed 1 mm.
A
* Operating Temperature Restrictions
• Ambient temperature, regardless of clearance A: 0 to 40 °C (or 0 to 35 °C when the PDP-S02-LR speaker system
is installed)
* Operating Temperature Restrictions for Upside-down Installations
• Ambient temperature, regardless of clearance A: 0 to 30 °C
NOTE: Different temperature restrictions apply to the PDK-5006. Refer to 4.5 Tiltable Plasma Display Mount Hardware.
In wall-mounting installation, allow adequate space (a clearance of 300 mm or more) above and below the
monitor set, as well as on the right and left.
28
Avoid blocking or covering this
104mm
area on the upper and lower sides.
Shaded areas (
) indicate attachment
points for mounting hardware.
104mm