INTELLICLEAN™ AUTOMATIC CLEANING SYSTEM
A detergent tank is integrated into the structure of the range hood and a pump will automatically
distribute cleansers onto both fans inside the unit when the INTELLICLEAN™ button is pushed.
Cleaning often can keep the inside of the rangehood clean and prolongs the life of the unit.

Operation Instructions

1.
Pour both cleanser and water to the marked level on the provided re ll container.
2.
Pour the mixture into the re ll hole on the top left hand side of the range hood. Be careful to
not over ll the reservoir. The volume of the reservoir is identical to the re ll container.
3.
In the event of an over ll. The over owing cleaner mixture will travel down into the transparent
oil capture tray below. This will be an indication to cease lling the reservoir.
4.
Press the IntelliClean™ button on the right-most side on the button controls to start the motor.
5.
The motor will discharge cleansers onto the fan at regular intervals to clean the inside of the
range hood. It will stop automatically once the cleaning cycle is nished.
6.
The oil capture tray will need to be removed and emptied when the marked line on the side
has been reached.
Precautions
1.
Only speci c rangehood cleaning detergent and dishwashing detergent can be used. Using
inappropriate cleaning liquids can clog the lines and damage the pump. For more information
on which cleaning solutions to use, please contact the manufacturer or a local agent closest to
you.
2.
Follow the water and cleanser mixture ratio closely. The water to detergent ratio should be 5:1.
3.
Users are advised to clean the range hood once a day. If may be cleaned more or less
frequently depending on individual needs.
4.
When re lling the unit with cleansing mixture, use only the container provided and take care to
not over ll the reservoir.
5.
Always start the cleaning cycle with an empty oil capture tray. This will prevent the tray from
being over lled by the refuse.
6.
Do not insert anything other than the cleansing mixture into the the re ll hole.
7.
The refill container and reservoir are of identical volume. The IntelliClean™ system will
discharge any excess cleaner into the oil capture tray below.
9