Teledyne 4M User Manual page 36

Area scan cameras
Table of Contents

Advertisement

36
Sp ecify the typ e of trigger overlap
p erm itted w ith the p reviou s fram e. This
d efines w hen a valid trigger w ill be
accep ted (or latched ) for a new fram e
Sp ecifies the d elay in m icrosecond s (μs)
to ap p ly after the trigger recep tion
before activating it
Select the logical line of the d evice to
configu re.
Read the p in associated w ith the logical
line
The p hysical p in location associate w ith
the logical line.
Sp ecify the voltage threshold requ ired to
recognize a signal transition on an inp u t
line.
Sp ecify if the selected p in is u sed as an
inp u t or ou tp u t signal
Set the p olarity of the line, w hether to
invert the selected inp u t or ou tp u t line
signal
Read the cu rrent statu s of the selected
inp u t or ou tp u t line
Sp ecify the m inim u m length of an inp u t
line voltage transition before
recognizing a signal transition.
Retu rns the cu rrent statu s of all available
line signals, at tim e of p olling, in a single
bit field .
Select w hich internal signal, event
d riven p u lse or softw are control state to
ou tp u t on the selected line.
N ote: the Line Mod e featu re m u st be set
to Ou tp u t.
Sets the d elay before the ou tp u t line
p u lse d u ration is ou tp u t. Ap p licable for
the Ou tp u t Line Sou rce featu re.
N ote: the Line Mod e featu re m u st be set
03-032-20107-01
Enables the softw are trigger bu tton.
Trigger Overlap
Trigger Delay
The d elay of the selected trigger in 1 µs
increm ents.
Line Selector
-CC1 / CC2 / CC3 / CC4 (Inp u ts)
-Line 1 (Inp u t)
-Line 2 (Inp u t)
-Line 3 (Ou tp u t)
-Line 4 (Ou tp u t)
Line N am e
Inp u t 1 / 2 / 3 / 4 / 5/ 6.
Line Pin
Read Only.
Association
Line Detection
Threshold _2_4 (2.4V)
Level
Threshold _6_0 (6V)
Threshold _12_0 (12V)
Line Mod e
-Inp u t (CC1 to CC4, Line 1 and Line 2)
-Ou p u t (Line 3 and Line 4)
Read Only.
Line Inverter
Polarity On
Polarity Off
Line Statu s
Line Debou ncing
Min 1 µs, Max 255 µs.
Period (µs)
Line Statu s All
The ord er is Line1, Line2, Line3, Line4,
CC1, CC2, ...
Ou tp u t Line
Off
Sou rce
Softw areControlled
Pu lseOnStartofExp osu re
Pu lseOnEnd ofExp osu re
Pu lseOnStartofRead ou t
Pu lseOnEnd ofRead ou t
Pu lseOnInp u t1
Pu lseOnInp u t2
Pu lseOnInp u t3
Pu lseOnInp u t4
Pu lseOnInp u t5
Pu lseOnInp u t6
Ou tp u t Line
Min 0 µs, Max 8388608 µs
Pu lse Delay
Falcon2 4M, 8M, and 12M Camera User's Manual