1.
SAFETY MEASURES
For the purpose of your own safety and in order to avoid the boiler's breakdown it is strictly prohibited
to:
-
Use the boiler when it is out of order;
-
Put the boiler into operation with no flue pipe installed or with a defective smoke exhauster;
-
All gas dangerous works, all technical service works and reparations of the boiler must be effectuated
only by a specialized service organization;
-
To effectuate boiler treatment, being in a state of alcohol or drug intoxication;
To insert changes into the boiler's construction
-
-
To touch the combustion products outlet pipe while the boiler is in operation, as the temperature of
heating of this pipe might exceed100
-
To use gas and water systems, and also the heating system, for earth bonding;
-
To touch the boiler if you are standing barefoot (or your shoes are wet) on wet floor;
-
To effectuate boiler treatment if it is not disconnected from the electric network and gas system;
-
To insert changes into the safety and control systems operation with no permission and indication from
the boiler's manufacturer
-
To damage and deform the elements of electrical wiring of the boiler, even if the electric power supply is
disconnected;
-
To expose the boiler to the impact of atmospheric precipitations.
In order to avoid poisoning with carbonic oxide the premise where the boiler is installed must have the
ventilation providing air exchange of not less than one premise volume per hour.
In case of long-term idle state of the boiler in winter time or if pipeline freezing danger appears it is necessary
to drain the heat carrier out of the boiler and the heating system.
Do not keep highly flammable and volatile substances (gasoline, solvents etc.) in the premise where the
boiler is installed.
At the boiler's normal operation and when the gas pipeline is in good order there should not be the smell of
gas in the premise.
IF YOU FEEL THE SMELL OF GAS:
1) Close the gas supply tap, located on the gas pipeline by the inlet into the boiler;
2) Open the windows and doors in order to ventilate the premise, providing maximum fresh air inlet;
3) Do not use electric appliances in order to avoid the appearance of spark;
4) Do not use the telephone in a gas-polluted premise
5) Do not smoke and do not use open fire (lighters, matches etc.)
6) Call the gas facility emergency operation service immediately.
Usage of the boiler when it is out of order or non-compliance with the above-listed rules of exploitation may
lead to an explosion or fire, or poisoning with gas or combustion products.
The first symptoms of poisoning are: heaviness in the head, strong palpitation, buzzing in the ears, swimming
of the head, general weakness. Later scant of breath, nausea, vomiting and disordered motor function may
appear. The injured person may lose consciousness.
In order to provide first aid at gas poisoning or combustion products poisoning it is necessary to:
Bring the injured person into the fresh air;
1)
2)
Call the ambulance;
Unclasp clothes that constrain breath;
3)
Give household ammonia to smell;
4)
5)
To cover warmly, but not letting to fall asleep.
Prehospital service at electricity impact must be provided immediately, if possible at the place of the
accident, calling the ambulance at the same time.
First of all the injured person must be released from the electricity impact as soon as possible. If it is not
possible to disconnect the electric installation from the power line, you should immediately start releasing the
injured person from conductive parts, using isolating objects.
Releasing the person from voltage, you should use a rope, stick, plank or any other dry object which doesn't
conduct voltage.
Prehospital service after releasing the injured person depends on his state. If he is conscious, you should provide
him profound rest for some time, not letting him move before the doctor arrives.
If the injured person breathes very poorly and convulsively, but the pulse can be felt, you must immediately do
the mouth-to-mouth or mouth-to-nose resuscitation. In case if there is no breath you must immediately bring the
injured person to a warm premise with fresh air and make resuscitation before the doctor arrives.
2.

TECHNICAL DESCRIPTION

Boiler's purpose

2.1.
Heating wall-hung combi boiler with forced heat carrier circulation «BaltGaz NEVALUX-8224»
o
С (for separate pipes of smoke exhaustion and air output);