Wells WATER-MAX Owner's Manual page 10

Installation use & care service
Hide thumbs Also See for WATER-MAX:
Table of Contents

Advertisement

INSTALLATION (continued)
CAUTION:
Hot Surface
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
Burn Hazard
WEAR PROTECTIVE
GLOVES AND GOGGLES
This procedure requires
operating Water-Max™
without the tank lid. Some
splashing may occur.
Splashed water will be very
hot.
INSTALLATION START-UP AND CHECKOUT
Countertop must be at least 17-1/2" deep to safely support the
dispenser.
Before turning on power or water to Water-Max™, visually verify:
a. Unit is level, air outlet guard in place, with all legs touching the
counter (countertop installation); or,
Wall brackets securely mounted to wall and unit properly and
securely mounted to brackets (all screws tight) with outlet guard
installed (wall mount installation).
b. All electrical connections properly made and tightened.
Water connections properly made.
c. Verify faucet is properly installed in tank.
Turn on water to Water-Max™. Visually inspect unit for leaks.
Apply power to Water-Max™. Install tank on Water-Max™ shelf (leave
tank lid off at this time). Press power switch to ON and observe
operation:
a. POWER INDICATOR will glow when POWER SWITCH is ON.
TANK INDICATOR will glow when tank is properly installed.
b. After a five second delay, Water-Max™ tank should begin filling.
STATUS INDICATOR will glow steadily while tank is filling,
indicating normal operation.
c. Within the first minute of operation, and while tank is filling,
CAREFULLY remove the tank from the shelf. Verify that water flow
stops when the tank is removed.
d. Reinstall the water tank. Verify that water flow stops when water
reaches the water level probe.
Press power switch to OFF. Discard all water generated thus far by
dispensing containers of water from the faucet until the tank is empty.
Remove the tank from the shelf. Install tank lid on tank.
Reinstall tank on Water-Max™. Press power switch to ON and allow
tank to fill. Monitor time to fill and record on the INSTALLATION
CHECKOUT form.
Test water temperature at faucet. Water should be at 202ºF minimum.