Chimney Components - Heatilator I60 Owner's Manual Installation And Operation

Wood burning fireplace
Hide thumbs Also See for I60:
Table of Contents

Advertisement

C. Chimney Components
The following pictures show only those chimney components which may be safely used with this fireplace.
Catalog #
Description
US
CAN
CAK5A
CA-
Chimney Air Kit
K5A
ID4
ID4
Insulated Duct/Outside Air
UD4
UD4
Uninsulated Duct/Outside Air
SL1106
SL406 Chimney Section - 6 in. (152 mm) long
SL1112
SL412 Chimney Section - 12 in. (305 mm)
long
SL1118
SL418 Chimney Section - 18 in. (457 mm)
long
SL1136
SL436 Chimney Section - 36 in. (914 mm)
long
SL1148
SL448 Chimney Section - 48 in. (1219 mm)
long
SL11
SL4
Chimney Stabilizer
SL1130
SL430 Chimney Offset/Return - 30 deg
FS538
FS538 Ceiling Firestop - Straight
FS540
FS540 Ceiling Firestop - 30 deg
AS10
AS10
Straight Attic Insulation Shield, 24 in.
(610 mm)
JB577
JB577 Chimney Joint Band
CB576
CB576 Chimney Bracket
RF570
RF570 Roof Flashing - Flat to 6/12 Pitch
RF571
RF571 Roof Flashing - 6/12 to 12/12 Pitch
TR11
TR444 Round Termination Cap
TR11T
TR442 Round Telescoping Termination Cap
TCT1175
Terra Cotta Termination Cap
ST1175
ST475 Square Termination Cap
DTO134
Short Octagon Decorative Cap
DTO146
Tall Octagon Decorative Cap
DTS134
Short Square Decorative Cap
DTS146
Tall Square Decorative Cap
CT56
CT56
Chase Top
LDS33
LDS33 Decorative Shroud - 3 ft x 3 ft (.91 m
x .91 m)
LDS46
LDS46 Decorative Shroud - 4 ft x 6 ft (1.22 m
x 1.83 m)
LDS-BV
LDS-
Decorative Shroud - 26 in. x 26 in.
BV
(660 mm x 660 mm)
Field Constructed Shrouds (See "Wood-
burning Termination Cap")
CT-11A
n/a
Adapter-May be used with the follow-
ing Copper Caps
n/a
CT-Series
n/a
DT-Series
14 in.
(356 mm)
5-1/4 in.
(133 mm)
13 in.
(330 mm)
CAK5A Chimney Air Kit
14 in.
(356 mm)
4 in. (102 mm)
SLA10 Adaptor
(Required in Canada)
Heatilator • I60, I80 • 4013-250 • Rev H • 1/11
ID4 Insulated Duct
42 in.
(1067 mm)
UD4 Uninsulated Duct
42 in.
(1067 mm)
11 in.
(279 mm)
Chimney Sections
Catalog #
US
CAN
in
SL1106
SL406
6
SL1112
SL412
12
SL1118
SL418
18
SL1136
SL436
36
SL1148
SL448
48
A = Actual Length
B = Effective Length (length of
chimney part after it has
been snapped to another)
20-3/4 in.
(527 mm)
18 in.
(457 mm)
SL11/SL4 Vent Stabilizer
4 in. (102 mm) i.d.
4 in. (102 mm) i.d.
A
13 in.
(330 mm)
B
A
B
mm
in
mm
152
4-3/4
121
305
10-3/4
273
457
16-3/4
425
914
34-3/4
883
1219
46-3/4
1187
Inside Diameter
SL4 - 10 in. (254 mm)
SL11 - 11 in. (279 mm)
Outside Diameter
13 in. (330 mm)
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I80

Table of Contents