Sidewalls/Surrounds; Frame The Fireplace - Heatilator I60 Owner's Manual Installation And Operation

Wood burning fireplace
Hide thumbs Also See for I60:
Table of Contents

Advertisement

C. Sidewalls/Surrounds
Adjacent combustible sidewalls must be located a minimum 24 in. (610 mm) from the fireplace opening.
Combustible and noncombustible mantel legs, surrounds and stub walls may be constructed within the gridded area,
Figure 6.3.
Grid represents
inch scale.
FLUSH
FRONT
22 3/8 in.
[568 mm]
24 in.
[610 mm]
Figure 6.3
Mantel Leg or Wall Projections (Acceptable on both sides of opening)
D. Frame the Fireplace
Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.
Framing across the top of fireplace must be above top standoffs.
2 in. (51 mm)
min. air space
clearance
from chimney.
Figure 6.4
Framing the Fireplace
20
A
B
C
A
B
* If interior of chase will be drywalled, add the thickness to
** Adjust header height for a raised floor under fireplace.
Heatilator • I60, I80 • 4013-250 • Rev H • 1/11
4 in.
BRICK
[102 mm]
FRONT
19 3/4 in.
[502 mm]
24 in.
Model
[610 mm]
I60
I80
Fireplace header cannot be
positioned until after the fireplace
assembly is in place.
Header MUST NOT be notched!
D = extra space needed for outside air connection.
If outside air duct has no bend, this dimension may be
reduced as long as minimum clearances are met.
D
Model
A
B*
in.
45 1/2
28
I60
mm
1156
711
in.
51 1/2
28 1/2
I80
mm
1308
724
this measurement.
A
B
inches
36
45
mm
914
1130
inches
42
50 1/2
mm
1067
1283
D
D
(4" duct)
(6" duct)
C**
50
8
12
1270
203
305
50
8
12
1270
203
305