Customer Service #: (570) 546-9663 · To Order Call: (800) 523-4777 · Fax #: (800) 438-5901
����� ����� � �� ���������� ���� ���������
PERFORMANCE CURVE
CFM
STATIC PRESSURE (Inch/H
O)
2
5 HP GRIZZLY DUST COLLECTOR PERFORMANCE RESULTS
Max CFM
Max SP
HP
Volts
Amps
Inlet Dia.
Impeller Dia.
3184
11.2
5
220
34
9"
13"
Restrictor Plate (Inches)
ø 9"
ø 8"
ø 7"
ø 6"
ø 5"
ø 4"
ø 3"
ø 2"
ø 1"
ø 0"
Static Pressure (Inch/H
O)
5.5
6.4
7.8
8.8
10.0
10.6
10.7
10.8
10.9
11.2
2
CFM
3184
2848
2415
1815
1284
827
617
503
450
0
The airflow test probe is located 1.5x duct diameter upstream from the air inlet.
Test pipe length is a minimum of 10x duct diameter.