EMS XtremeRGB-Ex1 User Manual page 20

Xtremergb range of video capture cards
Table of Contents

Advertisement

To run the dplinks program open the Run by clicking on Start/Run and type
press Enter.
The program will run, however no notifications are displayed.
Firmware Upgrades
The XtremeRGB-Ex2 cards allow firmware upgrade to be completed on site rather than returning the
card to EMS. Whenever a firmware upgrade is performed, LK1 MUST BE FITTED on the
XtremeRGB-Ex2. To perform the upgrade, follow the step-by-step instructions provided by the
upgrade application.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power
outage) it is possible to revert to the factory settings by powering down the system, temporarily
removing LK1 then powering up the system with the link removed. Once the system has rebooted,
replace the LK1 link (whilst the system is powered up) and restart the firmware upgrade process.
It should be noted that the latest driver installation program includes an automatic firmware update, if
required. Therefore, prior to installing the application and driver, ensure that LK1 is fitted.
Extended Display Identification Data (EDID) - Disable Links
EDID is data provided by a display monitor and sent to the graphics device detailing a monitors
capabilities thereby enabling a system to identify the type of monitor that is attached.
The graphics device installed on your machine will see the card as a monitor and will expect to
receive the EDID data from the card.
However, in rare circumstances it may be necessary that the XtremeRGB-Ex2 does not report an
EDID of any kind. In this instance EDID support can be disabled by removing links LK2 or LK3.
Removing the LK2 link will disable the EDID function on Channel 1 and removing LK3 will disable the
EDID function on Channel 2.
Software Installation
The XtremeRGB software (driver and application) is installed by inserting the CD that was shipped
with your card into your CD ROM drive. The installation process should start automatically.
Should the CD fail to autorun use Explorer to browse the CD, locate then double click on install.exe
file e.g. d:/install.exe and click on Install Software... and follow the installation wizard instructions as
prompted.
Regular software updates are available from our website: www.ems-imaging.com
Also available on the EMS CD:
The Release Notes - The release notes contain the latest information on the XtremeRGB-
Ex2
Installation instructions.
Release history
Known problems
Troubleshooting
The application Help File - Instructions on how to use the application. The help file is in
cd:/XtemeRGB_manual/XtremeRGB_help.pdf
Test patterns to assist in setting up an analog RGB / DVI source (see help file topic How to
set up an RGB / DVI Source)
and then
dplinks

Advertisement

Table of Contents
loading

Related Products for EMS XtremeRGB-Ex1

This manual is also suitable for:

Xtremergb-ex2Xtremergb-iiXtremergb-ex4+Xtremergb-ex8

Table of Contents