Installation - Harman XXV Installation & Operating Manual

Space heating appliance fired by wood pellets
Hide thumbs Also See for Harman XXV:
Table of Contents

Advertisement

installing
Place the stove on a non-combustible floor
protector that extends a minimum of 6 inches
to the front (152mm), 6 inches to the sides
(152mm) and flush with the rear of the hopper.
Front and side floor protection measurements
are made from the firebox or window opening.
Floor protection must also be positioned under
horizontal flue pipe. The minimum floor protec-
tor material is 20 gauge sheet metal. Other
floor protector materials are ceramic tile, stone,
brick, etc.
Place the stove away from combustible walls
at least as far as shown in Figures 2 and 3.
Note that the clearances shown are minimum
for safety but do not leave much room for access when
cleaning or servicing. Please take this into account when
placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect
the circuit board.) Also be sure that the polarity of the outlet
that the stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter.
(The draft meter must have a minimum range of 0-.5.)
Record the first reading. Connect flue pipe to stove and be
sure all doors and windows in the home are closed. Record
the second draft reading_______. If the second reading
is more than .05" lower than the first reading, check for
possible restrictions or the need for outside air (see page
10). For more information on the draft test procedure, refer
to Page 17.
Mobile home installation
When installing this unit in a mobile home several re-
quirements must be followed (Reference HUD Regulation
#24CFR3280):
1. The unit must be bolted to the floor. This can be done
by using clips (part # 2-00-677110B) and 1/4" lag screws.
2. The unit must also be connected to outside air. See
page 10.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.
cautiOn: this appliance must be vented to the out-
side.
cautiOn
the Structural integritY OF the
MObile hOMe FlOOr, wall, and ceiling/
rOOF MuSt be Maintained.
warning
Mobile home regulations do not allow
installation in a room designated for sleeping.

installation

3"
12"
Fig. 3
Floor Protector minimum: 32" X 32"
Fig. 4
*Measure front and side floor protection from the glass opening.
Fig. 5: Optional Top Vent Pipe Clearances
6.25"
Fig. 2
(813mm X 813mm)
32" minimum
18"
6" from
pipe to wall
6.25"
0"
6"
(152mm)
6" from
glass
4" from
back of top
flue vent to
wall
7
XXV Pellet Stove

Advertisement

Table of Contents
loading

Table of Contents