Heatilator EL36 Series Owner's Manual page 38

Installation and operation
Hide thumbs Also See for Heatilator EL36 Series:
Table of Contents

Advertisement

The fi replace burns the wood too fast. What can I do?
Diagnostic Questions
Do you have glass doors?
What is the condition of the
wood?
I smell smoke in the house during operation. What's causing that?
Diagnostic Questions
Does the fi re start and burn
well?
I smell smoke in the house after we've had a fi re in the fi replace. What is the cause/what can we do?
Diagnostic Questions
Is the damper closed?
Is the chimney clean?
38
Possible Causes of Condition
• Need to slow air intake
• Extremely dry wood
Possible Causes of Condition
No:
• Damper not fully open
• Chimney obstruction
• Not enough kindling and/or fuel to establish
draft
• Inadequate combustion air
Yes:
• Fire too close to front
• Competition with exhaust devices
Possible Causes of Condition
• No: Down draft or negative pressure
• Yes: Negative pressure from exhaust fans
and/or house stack effect.
• No: Creosote odor
• Yes: Damper closed too early
Heatilator • EL36/EL42 • 4044-132 Rev P • 02/07
Solutions
Add glass doors.
Mix in less seasoned wood after fi re established.
Solutions
Open damper; check and clean chimney if needed; use adequate
kindling and fuel; open glass doors or open window, check for
need for balanced air make-up.
Build fi re farther back. Do not use exhaust fans during startup
and/or check for need for balanced air make-up system.
Solutions
Close the damper at end of burn.
Check for need for glass doors. Check for need for balanced air
make-up system or raising chimney.
Have chimney cleaned.
Wait until fi re completely out before closing damper.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heatilator el42 seriesEl36 seriesEl42 series

Table of Contents