Non-Combustible Finish Materials
0 mm to 25 mm Thick Inside Fit Method
The Tonic decorative front is approved for inside fi t ap-
plications. Non-combustible fi nishing materials up to 25
mm thick can be installed around the front (left, right, top,
and bottom).
For the Tonic decorative front inside fi t applications, the
decorative front must be installed tight to the fi nishing
fl anges and must not overlap any fi nish material.
Ensure that no non-combustible fi nish materials are in-
stalled within 19 mm of the top of the fi replace opening,
or within 76 mm of the bottom of the fi replace opening.
The 19 mm spacing is required to provide clearance for
removing and installing the Tonic decorative front. See
Figure 13.14.
FACTORY-INSTALLED
NON-COMBUSTIBLE
BOARD
DRYWALL OR
EQUIVALENT
(10 mm)
Figure 13.13 Inside Fit Method (Tonic Decorative Front Only)
50
0-25 mm
(MAX)
19 mm
520 mm APPLIANCE
OPENING (HEIGHT)
76 mm
0-25 mm
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. D • 6/11
Non-Combustible Finish Material 0 - 25 mm Thick
19 mm
Figure 13.14 Noncombustible Surface Finishing Material
0 - 25 mm Thick-Inside Fit Method
(Tonic Decorative Front Only)
D. Decorative Fronts
WARNING! Risk of Fire! A decorative front is required
for this model. DO NOT operate this appliance without a
decorative front in place.
Only doors certifi ed for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used.
TONIC DECORATIVE FRONT
(TN-SLR-**)
Figure 13.15 Tonic Decorative Front
19 mm
76 mm
Bottom Joint
Inside and Overlap Method
See Section 13.C.

Advertisement