Heat & Glo XLR-PLUS-PB-AU Owner's Manual
Hide thumbs Also See for XLR-PLUS-PB-AU:
Table of Contents

Advertisement

Quick Links

Model:
XLR-PLUS-N-AU
XLR-PLUS-PB-AU
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT spray aerosols in the vicinity of this
appliance while it is in operation.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This is a room sealed appliance and no other ventilation is
required than what is provided.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• DO NOT place articles on or against this appliance.
• Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
SAI Global
Ref No GSCS20194
AS4553:2008
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo XLR-PLUS-PB-AU

  • Page 1 • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. This is a room sealed appliance and no other ventilation is required than what is provided. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215 Street West, Lakeville, MN 55044 Copyright 2012 • Printed in U.S.A. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 3: Congratulations

    The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace. Type of Gas SAI Global Certification Nº: DMS (mm) Model Number Serial Number xxxx-xxx Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 4: Table Of Contents

    E. Electrical Service and Repair ..... . 45 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 5 E. Contact Information ......77  = Contains updated information. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 6: Limited Lifetime Warranty

    Conditions, Exclusion, and Limitations listed Igniters, Electronic Components, and Glass 2 years Factory-installed blowers Molded refractory panels 3 years Firepots and burnpots 2000-645 (1-12) Page 1 of 3 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 7 HHT (8) modifi cation of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interrup- tions or fl uctuations of electrical power supply to the appliance. 2000-645 (1-12) Page 2 of 3 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 8 444 Swan Street 277 Lord Street 10 Martin Avenue Richmond 3121 East Perth 6000 Arncliff 2205 (03) 9429-5573 (08) 9228-2600 (02) 9597-7222 2000-645 (1-12) Page 3 of 3 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 9: Listing And Code Approvals

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 10: User Guide

    DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.E. CLEAR SPACE SECTION 2.C. Figure 2.1 General Operating Parts Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 11: Clear Space

    This appliance ships standard without a decorative media option. For installation and removal of these decorative media options, refer to installation instructions which ship with the media options. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 12: Lighting Instructions (Ipi)

    See installation and operating vice agency or the gas supplier. instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fireplace, please refer to www.fireplaces.com. Final inspection by Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 13: Control Module Operation

    SWITCH FLAME HI/LOW NG/LP GAS-TYPE STATUS SWITCH INDICATOR LED SELECTOR SWITCH Figure 2.3 Control Module Note: The HI/LO and LP/NG switches on the control module are non-functional on the XLR fireplace. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 14: After Fireplace Is Lit

    This is the normal response to prolonged heat exposure. The glass rock media may lose some or luster of its luster over time. See your dealer for replacement media. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 15: Maintenance And Service

    • The decorative media options DO NOT require routine • Reinstall door or decorative front. maintenance if they are properly installed. Refer to the installation instructions which ship the decorative media to verify correct installation Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 16: Maintenance Tasks-Qualified Service Technician

    • Gas pressure taps are accessible by removing the deco- rative front and fixed glass assembly. Refer to Section 11.A for information related to the gas valve and gas pressure settings. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 17: Getting Started

    REMAINS CLEAR ON ANY MANTEL PIECE INSTALLATION OPTIONAL WALL SWITCH HEATER MUST BE INSTALLED AND FLUE PENETRATION COMPLETE PRIOR TO FINISH SHEETING GAS LINE (SECTION 11) Figure 4.1 sta Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 18: Design And Installation Considerations

    Manometer Flat blade screwdriver Caulking material (149 °C (300 °F) minimum continuous exposure rating) One 1/4 in. (6 mm) female connection (for optional fan) Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 19: Framing And Clearances

    ONE 90° ELBOW See Section D. Inches 53-1/8 75-3/16 19-5/16 17-3/4 Figure 5.5 & 5.6 See Section D. Millimeters 1350 1220 1910 Figure 5.5 & 5.6 Figure 5.1 Appliance Locations Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 20: Constructing The Appliance Chase

    Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) Inches 8-11/16 42-1/8 18-1/8 1-1/8 1-1/8 3-1/2 Millimeters 1070 1270 Figure 5.2. Clearances to Combustibles Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 21: Mantel And Wall Projections

    (80 mm) 1 in. (25 mm) MINIMUM Figure 5.6 Non-Combustible Zone AIR SPACE Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Note: AIR SPACE denoted in Figure 5.6 is defined by the nailing tabs and top metal standoffs. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 22: Termination Locations

    39.8°-42.5° ............990 42.5°-45.0° ............1 220 45.0°-49.4° ............1 520 49.4°-53.1° ............1 830 53.1°-56.3° ............2 130 56.3°-59.0° ............2 290 59.0°-60.3° ............2 440 *910 mm minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 23 4. See Appendix J, Figure J1(a) and J2(a) for clearances required from a flue terminal to a LP Gas cylinder. A flue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 6.3 Minimum Clearances for Termination Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 24: Vent Information And Diagrams

    • Horizontal runs of vent do not require vertical rise; length of straight pipe is allowed between two 45º elbows horizontal runs may be level. (see Figure 7.1). Vertical 8-1/2 in. (216 mm) Horizontal Figure 7.1 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 25 1066 mm (3.5 ft.) 3.05 m (10 ft.) 1.2 m (4 ft.) 4.6 m (15 ft.) H Max. =4.6 m (15 ft.) V + H Max. = 12.2 m Figure 7.3 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 26 1.2 m (4 ft.) 4.6 m (15 ft.) H + H Max. = 4.6 m (15 ft.) V + H + H Max. = 12.2 m (40 ft.) INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 27 6-1/2 ft. - 44 ft. (2 m - 13.4 m), an exhaust restrictor may be needed. The exhaust restrictor is located in the appliance manual bag. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 28 Note: Use SLP Series components only. Note: All appliances that will burn butane must have a 12 in. (305 mm) vertical section of pipe before any other venting. Figure 7.8 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 29 Note: Use SLP Series components only. Note: All appliances that will burn butane must have a 12 in. (305 mm) vertical section of pipe before any other venting. INSTALLED HORIZONTALLY Figure 7.9 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 30 Maximum= 40 ft. (12.2 m) Note: All appliances that will burn butane must have a 12 in. (305 mm) vertical section of pipe before any other venting. Figure 7.10 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 31: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is 1 in. (25 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 32: Install The Ceiling Firestop

    Figure 8.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 33: Install Attic Insulation Shield

    • Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 34: Appliance Preparation

    For all venting applications, ensure that the pipe gasket is in place before attaching any pipe section. This gasket is shipped in place around the starting collar. See Figure 9.2. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 35: Securing And Leveling The Appliance

    Reference the Heat-Zone -240V Kit instructions for the ® remaining installation steps. REMOVE COVER PLATE ATTACH ® HEAT-ZONE -240V HERE Figure 9.4 Remove Cover Plate Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 36: Installing Vent Pipe (Slp Pipe)

    Use care when removing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent may leak. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 37: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 38: Disassemble Vent Sections

    3 mm larger than the support box outline. • Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure 10.9). Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 39: Install Metal Roof Flashing

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Figure 10.14 Assembling the Storm Collar Around the Pipe Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 40: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.16. Figure 10.16 Wall Thimble Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 41: Install Horizontal Termination Cap

    WARNING! Risk of Fire! the termination cap must be positioned so that the arrow is pointing up. • Use a high-temperature sealant gasket to seal between the pipe and exterior firestop. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 42: Gas Information

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed upstream from the gas control valve. Table 11.1 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 43: High Altitude Installations

    Reduce burner orifice 4% for each 1000 ft. (305 m) above 2000 (610 m). Figure 11.3. Remove Valve Plate 4. Lift the valve assembly up and out to make necessary service or repair. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 44: Electrical Information

    SENSE TO JUNCTION CORD GRAY MODULE RC300 4.5V DC (AAA X 3) WALL SWITCH JUMPER WIRE RC100 (OPTIONAL REMOTE CONTROL) THERMOSTAT WIRE ASSEMBLY / WALL SWITCH WIRE Figure 12.1 IntelliFire Plus™ Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 45: Junction Cord Information

    The service cord is found on the right exterior side of the unit. See Figure 12.3 for wire connection detail. Figure 12.2. Junction Cord Information 240V BLOWER GROUND TERMINAL TO FIREPLACE CHASSIS JUNCTION CORD AUX 300 CE Figure 12.3 Blower Circuit- Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 46: Control Module Operation

    220-240VAC, 50-60 Hz, and is required for a control module LOCK-OUT. operation of this remote control device. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 47 • Connect the equipment into an outlet on a circuit dif- ferent from that to which the receiver is connected. • Contact the dealer or an experienced radio TV techni- cian for help. Figure 12.6 Mounting Remote Control Housing Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 48 RC300AU will not be programmed if it’s in STANDBY mode. Press the ON/OFF button twice to switch to IDLE mode. CONTROL MODULE REMOTE POSITION AUX 300CE CABLE LEARN BUTTON Figure 12.11 Programming RC300AU Figure 12.9 AUX 300 module installation Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 49 Use the SELECT button to select the current Select feature. Menu Use the UP and DOWN arrows to toggle Menu through the menu functions and value selec- Select Select tions in the submenus. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 50 HEIGHT setting and will automatically adjust after 10 is off. When the fireplace is turned back ON, the AUX1 seconds. and AUX2 settings will be restored to the previous setting. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 51 NOTICE: No functions will be usable until child lock feature • Locate house circuit breaker for fireplace. is disabled. • Turn off the circuit breaker. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 52 At control module, turn off fireplace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 53: Finishing

    2. Screw each nailing tab to the adjoining framing material. Figure 13.2 Front Side Finishing Detail Ensure that the air space clearance is maintained on the sides of the fireplace. See Figure 13.2. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 54 It is acceptable to pre-drill holes and use self-tapped screws in the factory-installed non-combustible board to attach non-combustible backer board for tile, marble, etc. Refer to Figure 13.3 for acceptable screw location and screw length requirements. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 55 If a crack does emerge adjacent the fireplace, it can be permanently repaired by filling it with spackling paste or paintable latex caulk, followed by repainting. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 56: Mantel And Wall Projections

    1-1/8 in. (30 mm) FRAMING Figure 13.5 Clearances To Mantels Above Appliance. 1-1/2 in. (37 mm) Note: For non-combustible fireplace finish material (marble, stone, etc) specifications refer to Section 13.C. 3/8 in (10 mm) BUILDING MATERIAL Figure 13.7 Front Side Finishing Detail Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 57: Facing Material

    TONIC DECORATIVE 0 mm FRONT SHOWN Figure 13.9 Non-Combustible Finish Material Diagram for 0 - 1 in. (25 mm) Thick Overlap Fit Method (Tonic or Martini Decorative Front) NON-COMBUSTIBLE FINISHING MATERIAL 0 - 1 in. (25 mm) THICK DRYWALL OR EQUIVALENT 3/8 in. (10 mm) Figure 13.8 Overlap Fit Method (Tonic or Martini Decorative Front) Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 58: Decorative Fronts

    3 in. (76 mm) 1 in. (0-25 mm) TONIC DECORATIVE FRONT DRYWALL OR (TN-SLR-**) EQUIVALENT 3/8 in. (10 mm) Figure 13.12 Tonic Decorative Front Inside-Fit Method Only See Section 13.C. Figure 13.10 Inside Fit Method (Tonic Decorative Front Only) MARTINI DECORATIVE FRONT (MT-SLR-**) Figure 13.13 Martini Decorative Front Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 59 WARNING! Risk of Valve / Control Damage! This appliance requires field-installation of heat shields onto the firebox glass frame. Do not operate this appliance without the specified heat sheild(s). Gap between Tonic front and Tonic glass lip. This gap is for cool air flow when fan is running. Figure 13.17Tonic Front Gap Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 60: Appliance Setup

    4. Put pressure on the glass as you allow the glass assem- bly to drop into the two lower tabs. See Figure 14.1. 5. Tilt top of glass towards fireplace and engage both top spring latches Figure 14.2 Mesh Installation Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 61: Air Shutter Setting

    8. Repeat steps 1 & 2 to ensure proper functionality of 13 mm 5 mm 6 mm appliance. Propane Full Open 10 mm 13 mm Butane Full Open Full Open Full Open Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 62: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 5.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 5.7. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 63 Shutter Setting Check to assure correct shutter setting for your model and gas type. c. Gas Type Assure correct fuel matches unit gas model and compo- nents. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 64 At control module, turn off fireplace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 65: Component Access

    BURNER SUPPORT CLIP BATTERY PACK 8KI-CE AUX300CE VARIABLE 6V DC HEAT NOTE: BATTERY PACK IS LOCATED ON REGULATOR MODULE FLEX VALVE SHIELD ACCESS PANEL TO RIGHT OF VALVE. Figure 16.2 Valve Components Figure 16.4 Remove Burner Assembly Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 66: Access Through The Valve Assembly

    See Figure 16.6. VALVE ASSEMBLY GASKET Figure 16.6 Remove Valve Plate 4. Lift the valve assembly up and out to make necessary service or repair. 5. Replace gasket before reinstalling the valve assem- bly. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 67: Gas Valve Replacement

    (2) flare fittings. 5. Unscrew (2) screws located under the pressure taps to remove the gas valve from the valve bracket. VALVE GAS VALVE ORFICE FLEX BRACKET GAS INTLET FLEX FLARE FITTING PILOT FITTING PILOT FITTING Figure 16.9 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 68: Reference Materials

    RIGHT VIEW Location Inches Millimeters Location Inches Millimeters 1218 1092 37-3/4 16-5/8 13-3/4 6-5/8 39-9/16 1006 41-3/4 1060 3-1/2 2-3/16 6-7/8 1195 17-1/8 9-5/16 18-1/8 25-7/8 16-3/4 9-3/4 Figure 17.1 Appliance Dimensions Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 69: Maintenance Tasks

    2. Replace batteries in remote transmitters and battery-powered receivers. Carbon Deposition 1. Appliances incorporating a live fuel effect, and designed to operate with luminous flames, may exhibit slight carbon deposition. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 70: Vent Components Diagrams

    (241 mm) (352 mm) 14 in. (356 mm) DRC-RADIUS Cap Shield 5 in. (127 mm) 11-7/8 in. (302 mm) 13-7/8 in. (352 mm) DVP-BEK2 DVP-HPC Cap Brick Extension Figure 17.2 Vent Components Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 71 SLP36 SLP48 1219 DVP-HSM-B SLP-PIPE 51 - 152 SLP6A 2 to 6 Extended Heat Shield 51 - 305 SLP12A 2 to 12 SLP-FS SLP-WS SLP-HVS Ceiling Firestop Wall Shield Firestop Horizontal Pipe Support Figure 17.5 SLP Series Vent Components Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 72 Snorkel Termination Cap Support Box-Black Termination Cap SLP-DCF-BK SLP-WT-BK SL-2DVP Ceiling Firestop Wall Thimble-Black Adapter Black 12 in. (305 mm) 7 in. (178 mm) 15-1/2 in. (394 mm) DVP-FBHT SLP90 SL-2DVP DVP-FBHT Figure 17.6 SLP Series Vent Components Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 73 8-3/8 in. (140 mm) (146 mm to 213 mm) (213 mm) 3° 87° 15 in. 10-1/2 in. (381 mm) (267 mm) 10-7/8 in. (276 mm) SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 17.7 SLP Series Vent Components Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 74 Burner N 2264-007 Burner P & B 2264-008 Media Tray 2264-118 Bracket, J-Box 2264-154 Junction Cord 2222-374 Lower Cover Panel 2264-103 Additional service part numbers appear on following page. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 75 15.13 2166-306 Module, Gray 15.14 2166-305 DC Regulator 15.15 2166-340 Aux300 CE 15.16 2166-375 Jumper Wire 15.17 GFK-240V Fan Kit Additional service part numbers appear on following page. Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 76: Service Parts List

    Conversion Kit B P2B-XLR-PLUS Conversion Kit P N2PB-XLR-PLUS Pilot Orifice N 593-528 Pilot Orifice B 593-529 Pilot Orifice P 593-527 Regulator N NGK-DXV-50 Regulator P & B LPK-DXV-50 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...
  • Page 77: Contact Information

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2012 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12...

This manual is also suitable for:

Heat & glo xlr-plus-n-au

Table of Contents