MARTINI DECORATIVE FRONT
(MT-SLR-**)
Figure 13.16 Martini Decorative Front
TONIC FRONT
A
B
Figure 13.17. Dimensions of Tonic Decorative Front.
Table 1. Dimensions of Tonic Decorative Front.
A
Top of decorative front to bottom of appliance.
B
Bottom of decorative front to bottom of appliance.
C
Inside dimension of decorative front (width).
D
Outside dimension of decorative front (width).
E
Inside dimension decorative front (height).
F
Outside dimension of decorative front (height).
This appliance requires fi eld-installation of heat shield(s) on the
fi rebox glass frame. These shields function to manage convective
heat transfer during blower operation. These shields are critical
to the performance and reliability of the appliance because they
prevent overheating of gas control components.
For installation fi nished with the Martini decorative front, a single
lower glass heat shield is installed in the bottom of the glass
frame. This shield will be installed prior to installing the decorative
surround and glass. See Figure 13.18. It is also critical that the
required air space is maintained between the underside of the
Martini surround and the adjacent fi nishing materials. See Figure
13.19.
For installations fi nished with the Tonic decorative front, both an
upper and lower glass heat shields are installed in the top and
bottom of the fi rebox glass frame. These will be installed prior to
installing the framed mesh and the Tonic surround. See Figures
13.18 and 13.19.
WARNING! Risk of Valve / Control Damage! This appliance
requires fi eld-installation of heat shields onto the fi rebox glass
frame. Do not operate this appliance without the specifi ed heat
sheild(s).
Inside-Fit Method Only
See Section 13.C.
E F
C
D
670 mm
175 mm
991 mm
1.13 m
327 mm
495 mm
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. D • 6/11
UPPER GLASS HEAT SHIELD
(TONIC ONLY)
LOWER GLASS HEAT SHIELD
(MARTINI & TONIC FRONTS)
Glass Lip Heat Shield seats in glass frame.
Retain top upper glass heat shield with tinnerman clip on
each side of glass frame.
Figure 13.18 Glass and Heat Shield - Martini and Tonic
Figure 13.19 Martini Front Gap
Gap between Tonic front and Tonic glass lip. This
gap is for cool air fl ow when fan is running.
Figure 13.20 Tonic Front Gap
Gap below Martini front
must not be covered - it
is for cool air fl ow when
the fan is running.