C. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 38 mm. The heat shield is designed to be used on a
wall 102 mm to 184 mm thick. If wall thickness is less than 102 mm the existing heat shields must be
field trimmed. If wall thickness is greater than 184 mm a DVP-HSM-B will be required.
384 mm
305 mm
206 mm
381 mm
Figure 17.7 SLP Series Vent Components
203 mm
SLP-TRAP
Horizontal Termination Cap
330 mm
SLP-HRC-ZC-SS
HORIZONTAL TERMINATION CAP
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. D • 6/11
Heat
Shield
Term Cap
Max
Trap
Effective
Length
Effective Length
146 mm to 213 mm
140 mm
87°
SLP-HRC-SS
Minimum
Maximum
Effective Length
Effective Length
133 mm
235 mm
5-1/4 in.
9-1/4 in.
213 mm
267 mm
276 mm