B. Decorative Barrier Fronts
WARNING! Risk of Burns! A decorative barrier front is
required for this model. DO NOT operate this appliance
without a decorative barrier front in place.
Only decorative barrier fronts certified for use with this ap-
pliance model may be used. Contact your dealer for a list
of decorative barrier fronts that may be used.
Note: See appliance Owner's Manual for TV mounting
guidelines.
The decorative barrier fronts approved for use with this
appliance have been designed to be installed by two
methods: Overlap Fit or Inside Fit. Before beginning the
installation, it is important to determine which method will
be used.
Clean Face Trim Front (CFT)
Overlap Fit (0-1 Inch Thick Finishing Method)
Non-Combustible Finish Materials
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite.
Decorative Barrier Front
Clean Face Trim (CFT)
15-3/4 IN.
Figure 10.4 Minimum Finished Opening Dimensions - Clean Face Trim Front Method
Heat & Glo • MEZZO36-C/ST-C, MEZZO48-C/ST-C, MEZZO60-C/ST-C, MEZZO72-C/ST-C Installation Manual • 2600-980 Rev. D • 9/19
Note: When a Clean Face Trim decorative barrier front
is installed, the rectangular holes in bottom access panel
will be covered.
NOTICE: This one inch maximum not only includes the
decorative finish materials (marble, tile, slate, etc) but also
the thin set, lath and adhesive used to attach the decorative
finish material.
1. Remove bottom finishing template from bottom access
2. The non-combustible finish material, 0-1 inch thick,
WARNING! Risk of Fire! DO NOT apply finishing mate-
rial beyond the finishing guard. Appliance will overheat if
finishing material extends into appliance opening.
NOTICE: Decorative barrier front will not fit properly if
finishing material is applied beyond the finishing guard.
3. Follow Overlap Fit section of the instructions provided
Finishing Method
Overlap Fit
39-1/8 IN.MEZZO36-C/MEZZO36ST-C
51-1/8 IN.MEZZO48-C/MEZZO48ST-C
63-1/8 IN.MEZZO60-C/MEZZO60ST-C
75-1/8 IN.MEZZO72-C/MEZZO72ST-C
FIREPLACE VIEWING AREA
panel. Verify that factory-installed finishing guards are
installed to ensure finishing material does not extend
into the fireplace opening. See Figure 10.2 and 10.3.
should be installed up to the fireplace opening on all
four sides, including the bottom access panel, cover-
ing the eight rectangular holes. Refer to Figure 10.4
for minimum finished opening dimensions.
with decorative barrier front.
Material Thickness
0-1 inch
Trim Ring
Included & Used
61