2. Adjustable Maximum Temperature Setting

The Mira Extreme is fully performance tested and the maximum temperature has
been set under ideal installation conditions at the factory. The temperature stop is
set to 41°C and depressing the override will increase the temperature by 5°C to
approximately 46°C. Site conditions and personal preference may make it necessary
to reset these temperatures.
Note! An adequate supply of hot water at least 12°C above the required
temperature must be available for correct operation of the shower control.
Warning! Resetting the temperature of the temperature stop will also reset the
maximum temperature obtainable with the override operated.
2.1 Turn the temperature control knob
anticlockwise to the maximum
temperature stop. Do not depress
the override button.
2.2 Insert the end of the push-fit tool
under the temperature control knob,
inline with the temperature override
button, and lever off the temperature
knob.
2.3 Press the upper flow control button
to start the flow of water, allow the
water temperature to stabilise.