User Menu - Grindmaster 11 Operation And Instruction Manual

Grind master grind'n brew coffee system operation and instruction manual
Table of Contents

Advertisement

User Menu

The User Menu is accessed by pressing the SET key on the display board. Navigation is accomplished by pressing
the UP, DOWN and SET keys. Feedback to the user is shown by the 3-digit numerical display.
The User Menu exits after a 1 minute timeout or all modes are stepped through. This menu is disabled by the User
Lockout Jumper.
Brew Settings - Brew Cycle Selection
There are four independent settings for brew cycles: Regular Full Brew, Regular Half Brew, Decaf Full Brew and
Decaf Half Brew. The User Menu adjusts settings for the brew cycle selected by the keypad. For instance, if
you want to change settings for Decaf Half brew then set the keypad to the Decaf Hopper and Half Brew Size
before entering the User Menu. The keypad settings cannot be changed while the User Menu is displayed.
User Menu Navigation
Advancing through the menu is done by pressing the SET Key. Each parameter is adjusted by pressing the UP
and DOWN keys. Pressing and holding the UP and DOWN keys will quickly scroll through settings. The table
below shows how to step through this menu.
Step Setting
1
Temperature Scale between
°F or °C
2
Water Temperature
setpoint in °F or °C
3
Show Auger Time
the amount of coffee beans fed
into the grinder
4
Set Auger Time
the amount of coffee beans fed
into the grinder
5
Show Brew Time
Total amount of pour time for
the brew cycle
6
Set Brew Time
Total amount of pour time for
the brew cycle
7
Show Pulse Brew
8
Pulse Brew Pulse Number
sets the number of pulses in
the brew cycle
9
Pulse Brew Pour Time
sets the amount of pour time in
each pulse
10
Pulse Brew Delay Time
sets the amount of delay time
between each pulse
11
Show Low Temp No Brew
12
Set Low Temp No Brew
enable or disable
Grind'n Brew® Coffee Systems
Display
Displays the current
selection. Factory default
is "°F"
Displays the current
selection. Factory default is
"195" in °F or "91" in °C.
"At"
Displays the current
selection depending on Brew
Cycle
"br"
Displays the current
selection depending on Brew
Cycle
"P-b"
Displays the current
selection depending on Brew
Cycle
Displays the current
selection depending on Brew
Cycle
Displays the current
selection depending on Brew
Cycle
"Ltn"
Displays the current
selection. Factory default
is "YES"
Adjustments
"°F" or "°C"
"170" to "205" °F
"77" to "96" °C
None
"0.1" to "45.0" seconds
None
"0.01" to "6.00" in minutes.sec-
onds
None
"OFF" to "10"
"0.05" to "1.00" in
minutes.seconds
"0.05" to "1.00" in minutes.sec-
onds
None
"OFF" or "ON"