Mounting the hood body
• Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points.
• Hook the hood body onto the screws 12a.
• Fully tighten the support screws 12a.
• Adjust the screws Vr to level the hood body.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 125 mm,
the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body air outlet and the adapting
ring ø120-125 10 on the reducer flange.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Assemble the two halves of the hood body extension piece 14.
• Push fit the assembled hood body extension piece 14 onto the
air outlet.
• Push fit connection 15 onto the hood body extension piece 14.
• Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
• Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 or by cutting the hood body ex-
tension 14 along one of the thinner section channels denoting
the pre-fixed lengths, then reassemble as described previously.
• The air outlet directional grills 8a - 8b must be fitted after the
lower outlet duct has been installed.
• Ensure that the activated charcoal filters have been inserted.