Installation

Plumbing Connections

WATER CONNECTION
Cold Water Connection -- all models
Connect the appliance to quality water via a pres-
sure hose with 19mm (3/4") couplings. A shut off
valve is to be provided adjacent to the oven.
Hot Water Connection -- COS-8E and COS-20E
A hot water connection is recommended but not
required for the steam generator. To hook the
steam generator to hot water use the right sole-
noid as viewed from the rear of the oven.
12,7mm (1/2") Appliance Hose
With 19mm (3/4") Hose Fittings
Figure 8
WARNING!!
Operating the unit without the water regu-
lator installed will invalidate your warranty.
Water must meet the following minimum require-
ments:
Total Dissolved Solids (TDS) content will not ex-
D
ceed 30 parts per million.
Water PH must be 7.0 or higher
D
WARNING!!
The use of poor quality water will invali-
date your warranty.
Regulator
10
DRAIN CONNECTION
The drain vent assembly, included with the unit,
and a 50,8mm (2") pipe with standard drain pitch,
should be run to an open drain or connected to a
standpipe equipped with a vent. The waste water
can also be directed to a nearby floor drain.
Please use the drain vent assembly and a
50,8mm (2") pipe for drain connection. Flexible
hose which allows trapped water to accumu-
late in sagged runs must be avoided.
Oven
Drain
To drain
Figure 9
COS-6, COS-101, COS-101S and COS-8E single
or top sections
A 609,6mm (24") long standpipe must be con-
nected to the DWV. This allows the escaping water
vapor to exit above the inlet louvers on the back
panel.
Breather vent
Plumber installed
connection
Tee, hose and clamps
Plumber installed
connection to drain
or lower unit
Figure 10
50,8mm (2") drain