Installation

Plumbing Connections

WATER CONNECTION
NOTE: Hot water maximizes steam production but is not
required. Cold water may be supplied to both
inlets if hot water is not available.
Connect the appliance to quality water via a pressure
hose with 3/4" GHT (19mm) couplings. See below for
connections. A shut off valve is to be provided adjacent
to the oven.
WARNING!!
Operating the appliance without the water reg-
ulator installed will invalidate your warranty.
This product must be installed by a licensed Plumber or
Gas Fitter when installed within the Commonwealth of
Massachusetts.
DRAIN CONNECTION
The drain should be run to an open floor drain avoiding
flexible hose that could sag and allow trapped water to
accumulate. The customer must supply the piping from
the oven to the drain.
NOTE: The drain piping must consist of temperature
resistant material, greater than 160°F, and be
of adequate diameter not to cause flow restric-
tion. Improper materials may deform and cause
restrictions, thus affecting performance.
BCX-14G and BX-14G
CNVX-14G
WARNING!!
Connection must be carried out by a licensed
plumber, to an open or closed drain. The drain
must never end directly beneath the equip-
ment. The drain should not be located on the
same side the equipment controls are located.
Specific water/drain connection for City of Los Ange-
les
1. Each drain line from the appliance shall be routed
without dips or sags to terminate above the flood level
rim of an approved indirect waste receptor.
2. The appliance shall be installed in accordance with
the manufacturer's printed instructions and the LAPC
and LAMC, 1999 editions.
3. A backflow protection device may be required by lo-
cal codes. If so, install on the potable water system
directly ahead of the appliance. The backflow protec-
tion device shall be any of the following: an approved
pressure type vacuum breaker installed at least 12"
above the highest point of use, a double check valve
backflow preventer or a reduced pressure principal
backflow preventer.
BCX-14E and BX-14E
CNVX-14E
Figure 10
12
Gas connection
Electrical connection
Filtered/boiler
connection
Unfiltered/condensate and
spray hose connection