Daily Gun Care, Flushing, and Cleaning
3.
Clean the gun. (continued)
B. Disconnect the air supply line (C). See Fig. 24.
C
Fig. 24
C. Remove the air cap ring (12), air cap (19), air
cap seal (47), and fluid nozzle (20) as
instructed on page 8.
20
35
47
12, 19
Fig. 25
D. Soak the air cap ring (12), air cap (19), and
fluid nozzle (20) in soapy water.
E. Dip a soft-bristle brush into soapy water, point
the gun down, and clean the front of the gun.
Do not use a wire brush. See Fig. 26.
Fig. 26
02800
F. Clean the air cap ring, air cap, and fluid nozzle
daily, minimum, using a soft-bristle brush. See
Fig. 27. Clean out air cap holes with a soft im-
plement, such as a toothpick, to avoid damag-
ing surfaces.
02757A
Fig. 27
02775A
02011