DataTrak Operation
Symbol
22
Table 1:Diagnostic Codes
Code
Code Name
Runaway
(DataTrak only)
E-1
Diving Up
E-2
Diving Down
E-3
Low Battery
E-4
Service Component
1
(units with runaway
protection only)
E-4
Disconnected
Solenoid
(units with runaway
protection only)
E-5
Service Component
2
E-6
Blown Fuse
Diagnosis
Pump running faster
• Increased air pressure.
than set runaway
• Increased fluid output.
limit.
• Exhausted fluid supply.
Leak during
Worn piston valve or packings.
upstroke.
Leak during
Worn intake valve.
downstroke.
Battery voltage too
Low battery. Replace battery; see
low to stop runaway.
page 23.
Problem with
• Damaged solenoid.
stopping runaway.
• Damaged valve carriage.
• Runaway (RT, F
may be enabled with pump that
is not equipped with a runaway
solenoid valve. Enter setup
screen and disable runaway pro-
tection.
Solenoid is
• Solenoid unplugged.
disconnected.
• Damaged solenoid wires.
Solenoid is not
• Bracket and solenoid not tight
engaging piston cup
against air valve housing.
(112).
Problem with
• Sensors unplugged.
sensing valve
• Sensors mounted incorrectly.
movement.
• Damaged sensors.
• Damaged valve carriage.
Fuse is blown.
• Faulty solenoid or solenoid wir-
Replace fuse; see
ing.
page 23.
• Extreme temperatures (above
140°F [60°C]).
• Runaway (RT, F
may be enabled with pump that
is not equipped with a runaway
solenoid valve. Enter setup
screen and disable runaway pro-
tection.
Cause
. 8) protection
IG
. 8) protection
IG
313255F