Troubleshooting - Graco AirPro 312579 Instructions Manual

Gravity feed airspray gun 100 psi (0.7 mpa, 7 bar) maximum air inlet pressure
Table of Contents

Advertisement

Daily Gun Maintenance

Troubleshooting

Problem
Spray Pattern
Normal pattern.
Right
Spray Pattern
Dirty or damaged air cap or fluid
nozzle.
Wrong
Heavy top
or bottom
Spray Pattern
Pressure too high for viscosity of
material being sprayed.
Wrong
Split pattern
Spray Pattern
Dirty or distorted air horn holes.
Wrong
Gun spitting
Air getting into paint stream.
Damaged fluid nozzle seal (19).
Will not spray
Cup is empty.
Fluid control valve (8) turned too
far clockwise.
12
Cause
Solution
No action necessary.
Rotate air cap 180°.
If pattern follows air cap, problem is in air
cap (13). Clean and inspect. If pattern is
not corrected, replace air cap.
If pattern does not follow the air cap, the
problem is with the fluid nozzle. Clean
and inspect the nozzle. If the pattern is
not corrected, replace nozzle.
Reduce air pressure and increase mate-
rial viscosity.
Correct pattern by narrowing fan size with
fluid control valve (8).
Clean and inspect air cap. If pattern is not
corrected, replace air cap.
Check if cup is empty and fill.
Tighten fluid nozzle (11).
Check and tighten needle packing nut (17).
Check fluid nozzle (11) for damage.
Replace fluid inlet gasket (3)
Replace seal (19).
Fill cup.
Adjust valve (8) counterclockwise.