Graco 289353 Instructions - Parts Manual
Graco 289353 Instructions - Parts Manual

Graco 289353 Instructions - Parts Manual

Finex airspray package sprayer

Advertisement

Quick Links

Instructions - Parts
Finex Airspray
Package Sprayer
Package solutions for pumping and spraying finishing materials. For professional use
only.
Important Safety Instructions
Read all warnings and instructions in this manual and in
your respective pump manual. Save these instructions.
Models:
289353 with Finex Airspray Gun
100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
289354 with Finex HVLP Gun
100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
312473B
ENG
TI10823A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 289353 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graco 289353

  • Page 1 Read all warnings and instructions in this manual and in your respective pump manual. Save these instructions. Models: 289353 with Finex Airspray Gun 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure 289354 with Finex HVLP Gun 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure...
  • Page 2: Table Of Contents

    Related Manuals Contents Related Manuals ......2 Warnings ....... . . 3 Installation .
  • Page 3: Warnings

    Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
  • Page 4 Warnings TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. •...
  • Page 5: Installation

    Installation Grounding The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. Pump: use the ground wire and clamp (supplied). See .
  • Page 6: Components

    Controls and Components Controls and Components Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. Sprayer Controls • Pump air pressure regulator (C): a locking regula- tor to adjust air pressure to the motor and fluid outlet pressure of pump.
  • Page 7: Typical Installation

    Typical Installation . 2: Typical Installation (Finex Airspray Gun Shown) Key: Pump Bleed-type Master Air Line Shutoff Valve Pump Air Pressure Regulator Gun Air Pressure Regulator Gun Fluid Pressure Regulator Air Filter 312473B Hose Set Suction Hose Pump Ground Wire (required) Main Air Supply Line Spray Gun, Finex Airspray or HVLP Bleed Type Master Air Valve...
  • Page 8: Pressure Relief

    Pressure Relief Pressure Relief Follow pressure relief procedure when you stop spray- ing and before cleaning, checking, or servicing the equipment. 1. Shut off the bleed-type air valve. TI10826A 2. Hold the gun firmly against a grounded metal pail and trigger the gun. Setup/Installation Before using the equipment for the first time, follow this procedure.
  • Page 9: Grounding

    Grounding Read Fire and Explosion Hazard. See page 3. 1. Connect the ground wire clamp to a true earth ground. 2. Ground the object being sprayed, fluid supply con- tainer, and all other equipment in the spray area. TI10832A 3. Ground all solvent pails. Use only metal pails. Do not place on a non-conductive surface such as paper or cardboard.
  • Page 10: Prime

    Prime Prime 1. Shut off both air regulators and the bleed-type air valve. TI10836A 2. Shut off the fluid regulator. 3. Install the air cap. TI10834A 4. Place the suction tube in the fluid. 5. Open the bleed-type air valve. TI10827A 6.
  • Page 11: Spraying

    Spraying 1. Adjust fluid flow using the pump air regulator or the fluid pressure regulator. TI10836A 2. Adjust fluid pressure so stream from gun travels 6–8 in. straight before falling off. 6 in. to 8 in. (152 mm to 203 mm) 3.
  • Page 12: Maintenance

    Maintenance Maintenance Relieve pressure before servicing. See Typical Installation, page 7. 1. Flush. See Flush, page 9. 2. Clean the air cap and fluid nozzle. TI10840A TI10834A 3. Clean the suction tube and inlet strainer, using a compatible solvent. TI10841A 4.
  • Page 13: Troubleshooting

    Troubleshooting Relieve pressure before servicing. See Typical Installation, page 8. Problem Pump will not run, or stops. Pump runs erratically. Pump runs too fast. Pump cycles at stall or fails to hold pressure at stall. Audible air leak. Air bubbles in fluid. Poor finish or irregular pattern.
  • Page 14: Parts

    Parts Parts 289353 with Finex Airspray Gun 289354 with Finex HVLP Gun Ref. Part Description 289609 PLATE, mounting D31331 PUMP, diaphragm 164856 FITTING, nipple, reducing 15D921 LEG, right, (finished) 15D922 LEG, left, (finished) 241976 REGULATOR, press, fluid 162453 FITTING, 1/4 NPSM X 1/4 NPT...
  • Page 15: Dimensions

    Dimensions 19.26 in. (48.92 cm.) TI10874A Technical Data Maximum fluid working pressure ... . . 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure ... . . 100 psi (0.7 MPa, 7 bar) Operating temperature range .
  • Page 16: Graco Standard Warranty

    Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for:

289354312473bTi10823a

Table of Contents

Save PDF