Airless/air-assisted sprayer 2800 psi (193 bar, 19.3 mpa) maximum working pressure airless spraying (70 pages)
Summary of Contents for Graco AirPro 312579
Page 1
Instructions-Parts ™ AirPro Feed Airspray Gun Conventional, HVLP, and compliant guns for specialty industrial applications. For professional use only. 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 3 for model information.
Models Gravity Feed without Cup Conventional Orifice HVLP/Compliant Size Air Pressure in. (mm) Model Series psi (MPa, bar) 0.055 (1.4) 289002 0.070 (1.8) 289003 Gravity Feed with Plastic Cup Conventional Orifice HVLP/Compliant Size Air Pressure in. (mm) Model Series psi (MPa, bar) 0.055 (1.4) 289011 0.070 (1.8) 289012 Gravity Feed with 3M...
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. Refer back to these warnings. Additional, product- specific warnings may be found throughout the body of this manual where applicable.
PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: •...
Setup Setup • Check that your shop air provides adequate air flow. See Technical Data, page 20, for minimum cfm requirements. • Recommended 5/16 in. (7.9 mm) ID hose, optional 3/8 in. (10 mm) ID air hose. • Set shop air pressure regulator (not supplied) according to paint manu- facturer’s recommendation.
Adjust Spray Pattern 1. Rotate the air cap to achieve desired spray pattern. See F . 2. 2. To achieve full fan pattern, open the air control valve by turning the knob fully coun- terclockwise. See F . 3. 3. To create a round pattern, turn the pattern air off by turning the air control valve fully clockwise.
Operation Operation Pressure Relief Procedure 1. Turn off the gun air supply. 2. Trigger the gun to relieve pressure. Apply Fluid CAUTION Excessive atomizing air pressure can increase over-spray, reduce transfer efficiency, and result in a poor quality finish. Regulatory agencies in certain states prohibit the operation of a spray gun above 10 psi (69 kPa, 0.7 bar) atomizing air cap pressure.
Daily Gun Maintenance General Tasks Follow the Pressure Relief Procedure, page 8. • Frequently lubricate the gun moving parts with a drop of non-silicone oil. • Do not disassemble the spray gun if you are having a spray pattern problem. See Troubleshooting, page 11, for information on how to correct the problem.
Daily Gun Maintenance Clean Nozzle and Air Cap 1. Remove air cap (13), trigger gun, remove nozzle (11), and soak both in a compatible cleaning solution. CAUTION Trigger the gun whenever you tighten or remove the nozzle. This keeps the needle tip away from the nozzle seating surface and prevents the tip from being damaged.
Daily Gun Maintenance Troubleshooting Problem Spray Pattern Normal pattern. Right Spray Pattern Dirty or damaged air cap or fluid nozzle. Wrong Heavy top or bottom Spray Pattern Pressure too high for viscosity of material being sprayed. Wrong Split pattern Spray Pattern Dirty or distorted air horn holes.
Page 13
Problem Excessive air Loose fluid nozzle (11). blowing back Damaged fluid nozzle seal (19). Excessive air leak Worn u-cups/air valve. behind trigger. Worn trigger. 312579H Cause Tighten fluid nozzle (11). Replace seal (19). Repair gun (Kit 289408). Be sure to use all included parts.
Repair Repair Follow Pressure Relief Procedure, page 8. See Parts, page 16, for callout references. Disassembly 1. Unscrew retaining ring (14) to remove air cap (13b). Check o-rings (13a and 13c) and replace if necessary. 2. Trigger gun while unscrewing nozzle (11) to prevent needle damage.
Reassembly 1. Install air control valve assembly (5) with valve turned fully counterclockwise to outer- most position. Torque to 85-90 in-lb (9.6-10.2 N•m). 2. Install air inlet valve assembly (27) with valve turned fully counterclockwise to outer- most position. Torque to 205-215 in-lb (23.2-24.3 N•m).
Parts Parts Pull trigger before installing nozzle (11). Insert spreader (15) with tapered end facing rear of gun. Insert u-cup (16) with open end facing front of gun. Apply lubricant. Apply low strength thread retainer. Apply thread sealant. Torque to 85-90 in-lb (9.6-10.2 N•m). Torque to 15-20 in-lb (1.7-2.2 N•m).
Page 17
Ref. Part No. Description 1❄ BODY, gun 3❄† GASKET, fluid inlet 4❄ 289792 FITTING, fluid inlet, includes gasket (item 3) 289796 VALVE, air control assembly 6*★ 289039 VALVE, air, assembly 289052 NUT, air valve, u-cup assembly 289097 VALVE, fluid control See p.
Repair Kits Without Gravity Cup Nozzle Size Model Spray Type in. (mm) 289002 Conventional 0.055 (1.4) 289003 Conventional 0.070 (1.8) 289005 HVLP 0.055 (1.4) 289006 HVLP 0.070 (1.8) 289008 Compliant 0.055 (1.4) 289009 Compliant 0.070 (1.8) With Gravity Cup Nozzle Size Model Spray Type in.
Technical Data Technical Data Maximum Air Inlet Pressure ..... 100 psi (0.7 MPa, 7 bar) Maximum HVLP/Compliant Inbound Air Pressure: HVLP gravity feed .
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.