CE750 User Manual FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE. This ATEN product is specifically designed and manufactured for the operation and management of computer mainframe and communications equipment used in network management centers. As such, it may not be completely appropriate for those environments and sites where special standards for performance and high reliability are required –...
An overview of the information found in the manual is provided below. Chapter 1, Introduction, introduces you to the CE750 system. Its purpose, features and benefits are presented, and its front and back panel components are described.
For information about all ATEN products and how they can help you connect without limits, visit ATEN on the Web or contact an ATEN Authorized Reseller. Visit ATEN on the Web for a list of locations and telephone numbers: International http://www.aten.com...
Because it allows access to a computer system from a remote console, the CE750 is perfect for use in any type of installation where you need to place the console where it is conveniently accessible, but you want the system equipment to reside in a safe location –...
CE750 User Manual Features Local and Remote Units connect at distances up to 150 m using Cat 5e cable. Dual console operation – control your system from both the local and remote USB keyboard, monitor, and mouse consoles Built-in ASIC for greater reliability and compatibility...
Cat 5e cable is the minimum required to connect the Local and Remote CE750 Units. Cable of a lower standard will result in degrading of the video signal. For best performance, we strongly recommend Cat 5e cable.
CE750 User Manual Operating Systems Supported operating systems are shown in the table, below: Version Windows 2000, XP, Vista Linux RedHat 7.1 and higher SuSE 9.0 and higher Mandriva (Mandrake) 9.0 and higher UNIX FreeBSD 4.2 and higher Novell Netware...
CE750L (Local Unit) Front View Component Description KVM Port Section If you are combining the CE750 with a KVM switch, the USB KVM cable that links to the respective ports on the Console section of the switch plugs into these ports.
CE750 User Manual CE750R (Remote Unit) Front View Component Description RS-232 Serial Port RS-232 serial devices – such as touchscreens or barcode scanners – plug into this port. Picture Compensation These pushbuttons adjust the video quality of the Pushbuttons remote console. See Picture Compensation, page 18 for details.
Chapter 1. Introduction CE750L / CE750R Rear View Side View Component Description Power Jack The cable from the DC Power adapter connects here. Audio Ports These mini stereo ports are for the speakers (green) and microphone (pink). Remote I/O The Cat 5e cable that connects the Remote and Local Units plugs in here.
Page 16
CE750 User Manual This Page Intentionally Left Blank...
Chapter 2 Hardware Setup 1. Important safety information regarding the placement of this device is provided on page 21. Please review it before proceeding. 2. Make sure that the power to all devices connected to the installation are turned off. You must unplug the power cords of any computers that have the Keyboard Power On function.
Page 18
CE750 User Manual 2. Screw the bracket into any convenient location on the rack. Note: These screws are not provided. We recommend that you use M5 x 12 Phillips Type I cross, recessed type screws.
Chapter 2. Hardware Setup Installation Grounding To prevent damage to your installation it is important that all devices are properly grounded. 1. Use the two grounding wires supplied with this package to ground both units by connecting one end of the wire to the grounding terminal, and the other end of the wire to a suitable grounded object.
Page 20
CE750 User Manual 3. For increased grounding protection, use STP (shielded twisted pair) cable to connect the Local and Remote Units. There are two methods that can be used: a) In addition to the eight paired wires, STP cable also contains a grounding wire.
Each connector is marked with an appropriate icon to indicate which it is. Note: If you are combining the CE750 with a KVM switch, the other end of the USB KVM cable plugs into the appropriate ports on the KVM switch.
Chapter 3 Operation Operating Modes The CE750 USB KVM Extender has three operating modes: Local, Auto, and Remote, as described in the table below: Mode Description Local Only the local console has KVM access. The remote console’s keyboard and mouse input is disabled.
CE750 User Manual Note: Remote mode cannot be selected. The remote console can get control only when the Operating Mode Pushbutton on the CE750L is toggled to Auto and the local console is idle. If the remote console is then idle for more than five seconds, the local console can gain access.
Chapter 3. Operation LED Display The CE750 Local and Remote Units have front panel LEDs to indicate their operating status, as shown in the tables, below: CE750L (Local Unit) Operating Mode Local Auto Local Lights to indicate Lights when the local console is active (the Remote...
Page 28
CE750 User Manual This Page Intentionally Left Blank...
Appendix Safety Instructions General Read all of these instructions. Save them for future reference. Follow all warnings and instructions marked on the device. Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result. Do not use the device near water.
Page 30
CE750 User Manual If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating. Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
Appendix Rack Mounting Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack.
CE750 User Manual Technical Support Technical support is available both by email and online (with a browser over the web): International Email Support support@aten.com Online Technical Support http://support.aten.com Support Troubleshooting http://www.aten.com Documentation Software Updates Telephone Support 886-2-8692-6959 North America Email Support ATEN TECH support@aten-usa.com...
Appendix Specifications Function CE750L CE750R Connectors Console Keyboard 1 x USB Type A Female (White) Ports Video 1 x HDB-15 Female (Blue) Mouse 1 x USB Type A Female (White) Speakers 1 x Mini Stereo Jack Female (Green) Mic. 1 x Mini Stereo Jack Female (Pink) RS-232 1 x DB-9 Female 1 x DB-9 Male (Black)
CE750 User Manual Troubleshooting Overview Operation problems can be due to a variety of causes. The first step in solving them is to make sure that all cables are securely attached and seated completely in their sockets. Problem Action No video Make sure that all cables are securely plugged into their sockets.