Using The Remote Control; Functions Of Buttons; Timer Values - JEM ZR33 HI-MASS User Manual

Table of Contents

Advertisement

ZR33-DMX USER GUIDE

Using The Remote Control

Fog Button
Stand-by Button
FOG
ON
5
4
6
3
7
2
8
1
9
POWER
OUTPUT
Power LED
Delay Time Control
Output Control
The
ZR33
comes with a comprehensive controller that allows the user to
manually fire the machine, or set a well featured timer to operate the
machine automatically. When the "ready" LED is lit at the rear of the
machine the remote becomes functional and the "fog" button will operate
the machine when pressed. Sometimes a pre-determined amount of smoke is
needed and the
ZR33
remote has a timer that will operate over a wide
range or varying times. The x8 timer value gives even greater flexibility
when a longer delay and run time are needed.
PAGE 6
MARTIN MANUFACTURING (UK) PLC
Timer Value Button
Timer Engage Button
STAND-BY
TIMER
ON
x8
ON
5
5
4
6
4
6
3
3
7
7
2
8
2
8
1
9
1
9
CYCLE
RUN
DELAY
Timer Cycle LED
Run Time Control
ZR33-DMX USER GUIDE
Functions
FOG BUTTON: Will when the machine has reached operating temperature fire
the machine when pressed and held.
STAND-BY BUTTON: This turns the machines electronics on and off.
TIMER VALUE BUTTON: When the timer is being used, the timer values can be
adjusted by a factor of 8, i.e. a 5 second minimum run time becomes 40 seconds &
a 10 second delay time becomes 1 minute 20 seconds.
TIMER ENGAGE: This will engage the timer to fire the machine according to the
present settings.
OUTPUT CONTROL: Turning this knob clockwise will increase the output of the
machine, if turned fully anti-clockwise there will be no output.
DELAY TIME CONTROL: This will adjust the amount of time the machine waits
between operating when the timer is engaged.
RUN TIME CONTROL: This will adjust the time the machine will operate for
when the timer is engaged.
POWER LED: This LED will light when the machine is switched on
CYCLE LED: This LED will light when the timer is engaged and the machine is
operating.

Timer Values

Run Time: X1 mode
Minimum = 2 seconds
Maximum = 18 seconds
Delay Time: X1 mode
Minimum = 2 seconds
Maximum = 18 seconds
An extension lead is available from JEM for using the controller out of
the machine.
MARTIN MANUFACTURING (UK) PLC
Run Time: X8 mode
Minimum = 16 seconds
Maximum = 2 minutes 24 seconds
Delay Time: X8 mode
Minimum = 16 seconds
Maximum = 2 minutes 24 seconds
PAGE 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zr33-dmx

Table of Contents