Condensing Unit Specifications Gsx130(18-60)1A - Goodman GSX Technical Manual

Gsx 13 seer series single phase condensing units with r-410a
Table of Contents

Advertisement

CONDENSING UNIT SPECIFICATIONS
Cooling Capacity, BTUH
Compressor
R.L. Amps
L.R. Amps
High Pressure Switch
Open
Close
Condenser Fan Motor
Horsepower
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
(1)
Minimum Circuit Ampacity
Maximum Overcurrent Device
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
Cooling Capacity, BTUH
Compressor
R.L. Amps
L.R. Amps
High Pressure Switch
Open
Close
Condenser Fan Motor
Horsepower
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
(1)
Minimum Circuit Ampacity
Maximum Overcurrent Device
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
(1)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
* Line sizes denoted for less than 25' line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to
the Installation and Operating Instructions and/or the long line-set guidelines.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
6
GSX130181A*
GSX130241A*
18,000
24,000
9.00
13.4
48.0
58.3
610 PSIG
610 PSIG
420 PSIG
420 PSIG
1/6
1/6
1.10
1.10
3/8"
3/8"
3/4"
3/4"
120.0
116.0
208/230-60-1
208/230-60-1
12.3
17.9
(2)
20
30
1/2 or 3/4
1/2 or 3/4
178
178
GSX130421A*
GSX130481A*
42,000
48,000
17.9
19.8
112.0
109.0
610 PSIG
610 PSIG
420 PSIG
420 PSIG
1/6
1/4
1.10
1.50
3/8"
3/8"
7/8"
7/8"
151.0
166.0
208/230-60-1
208/230-60-1
23.5
26.3
(2)
40
45
1/2 or 3/4
1/2 or 3/4
219
225
GSX130301A* GSX130361A*
30,000
36,000
12.8
16.6
64.0
79.0
610 PSIG
610 PSIG
420 PSIG
420 PSIG
1/6
1/6
1.10
1.10
3/8"
3/8"
3/4"
3/4"
129.0
131.0
208/230-60-1
208/230-60-1
17.1
21.9
30
35
1/2 or 3/4
1/2 or 3/4
180
197
GSX130601A*
60,000
26.4
134.0
610 PSIG
420 PSIG
1/4
1.50
3/8"
7/8"
184.0
208/230-60-1
34.5
60
1/2 or 3/4
240
GSX130[18-60]1A*