Wiring Diagram - Goodman A/GPG13 M SERIES Installation And Operating Instructions Manual

Single package gas-electric heating & cooling unit
Hide thumbs Also See for A/GPG13 M SERIES:
Table of Contents

Advertisement

L1
SUPPLY VOLTAGE
208-230/1/60
CC T1
R
L1
C
COMP
S
H
CAP1
(HIGH)
C
L1
(LOW)
L1
H
L1
D1
TRANS
L1
1
FUSE
FS
4
LS
5
ALS
3
IIC
6
PS
8
ECON
7
9
10
12
11
R
G
W
Y1
TO THC
INSTALLER/SERVICEMAN
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
EQUIP. STATUS
STATUS LIGHT
ON
NORMAL OPERATION
NO POWER OR
OFF
INTERNAL CONTROL
FAULT
IGNITION FAILURE
1 BLINK
OR
OPEN ROLLOUT
SWITCH
OR
OPEN AUX. LIMIT
SWITCH
2 BLINKS
PRESSURE SWITCH
OPEN
PRESSURE SWITCH CLOSED
3 BLINKS
WITHOUT INDUCER ON
OPEN LIMIT SWITCH
4 BLINKS
5 BLINKS
FALSE FLAME SENSED
6 BLINKS
COMPRESSOR
OUTPUT DELAY
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
*PG13(24,30,36,42)1** WIRING DIAGRAM
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
L2
CH
NOTE 3
T2
L2
C
CC
CAP 2
F
CM
NOTE 4
EM
L2
VM
L2
L2
NOTE 2
IGN
FS
RS
GV
CC
HPS
NOTE 5
6 5
PL
3
Y/Y2
C
CHECK
-
CHECK INPUT POWER
CHECK FUSE ON CONTROL
REPLACE CONTROL
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
FLAME ROLLOUT
BAD SWITCH
AUX. LIMIT OPEN
CHECK
PRESSURE SWITCH
CHECK
PRESSURE SWITCH
MAIN LIMIT OPEN
BAD SWITCH
STICKING GAS VALVE
3 MIN. COMP.
ANTI-CYCLE TIMER
COMPONENT LEGEND
ALS AUXILIARY LIMIT SWITCH
CAP CAPACITOR
COMP COMPRESSOR
CM CONDENSER MOTOR
CC CONTACTOR
CH CRANKCASE HEATER
EM EVAPORATOR MOTOR
FS FLAME SENSOR
GV GAS VALVE
IIC INTEGRATED IGNITION CONTROL
IGN IGNITOR
LS LIMIT SWITCH
PL PLUG
PS PRESSURE SWITCH
RS ROLLOUT SWITCH
THC THERMOSTAT HEAT & COOL
TRANS TRANSFORMER
2
VM VENT MOTOR
HPS HIGH PRESSURE SWITCH
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. CRANKCASE HEATER (OPTIONAL).
4. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING
SPEED AT COOL TERMINAL (IIC). CHANGE HEATING SPEED AT HEAT
TERMINAL (IIC)
4 SPEED MOTOR
B - HIGH SPEED
BL - MEDIUM HIGH SPEED
Y - MEDIUM LOW SPEED
R - LOW SPEED
4
5. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING
2
1
IN RETURN AIR COMPARMENT.
6. USE COPPER WIRE
THC-NO ECONOMIZER
W
G
R
Y
BL
28
WIRE SPLICE
MARKED TERMINAL
UNMARKED TERMINAL
WIRING
LINE VOLTAGE
LOW VOLTAGE
FIELD INSTALLED POWER
FIELD INSTALLED CONTROL
WIRE CODE
B
BLACK
BL BLUE
BR BROWN
G
GREEN
O
ORANGE
PK PINK
PU PURPLE
R
RED
W
WHITE
Y
YELLOW
BL/PK BLUE/PINK
3 SPEED MOTOR
B - HIGH SPEED
BL - MEDIUM SPEED
R - LOW SPEED
THC-FIELD WIRING
2 STAGE COOLING WITH ECONOMIZER
W
W
G
G
R
R
PU
Y
Y
C
BL
0140G01233 REV. A
208-230/1/60
W
G
R
Y1
Y2
C