Setup the RADIUS server and assign the client IP address to the Web-Smart switch. In this case, field in the default IP
Address of the Web-Smart switch with 192.168.0.100. And also make sure the shared secret key is as same as the one
you had set at the switch RADIUS server – 12345678 at this case.
The IP address of the RADIUS server being added.
The UDP port used by this server. The valid range is 0 - 65535.
The default UDP Port No. is 1812
Indicates if the shared secret for this server has been configured.
Selects the port to be configured. When the selection is changed, a screen
refresh will occur causing all fields to be updated for the newly selected port.
This selector lists the options for control mode. The control mode is only set if the
link status of the port is link up. The options are:
• Auto: The authenticator PAE sets the controlled port mode to reflect the
outcome of the authentication exchanges between the supplicant,
authenticator, and the authentication server.
• Force authorized: The authenticator PAE unconditionally sets the controlled
port to be authorized.
• Force unauthorized: The authenticator port access entity (PAE)
unconditionally sets the controlled port to unauthorized.
This field indicates the configured control mode for the port.
This button begins the re-authentication sequence on the selected port. This
button is only selectable if the control mode is 'auto'. If the button is not selectable,
it will be grayed out. Once this button is pressed, the action is immediate. It is not
required to press the Submit button for the action to occur.
This button begins the re-initialization sequence on the selected port. This button
is only selectable if the control mode is 'auto'. If the button is not selectable, it will
be grayed out. Once this button is pressed, the action is immediate. It is not
required to press the Submit button for the action to occur.
This button redirect to the "802.1X Statistics" page on the selected port.
This button begins the re-authentication sequence on the all ports.
This button begins the re-initialization sequence on all ports.