Installation: use the pipe holder. Always
engage the gasket. Then continue with
the gas connection. The flexible pipe is
prepared for apply when:
– it can not get hot more than room
temperature, higher than 30 °C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting
edges or corners;
– it can be easily examined in order to
check its condition.
The control of preservation of the flexi-
ble pipe consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its
full length;
– the material is not hardened, but
shows its correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
When installation is complete,
make sure that the seal of each
pipe fitting is correct. Use a
soapy solution, not a flame!
The gas supply ramp is on the rear side
of the control panel.
WARNING!
Before gas connection discon-
nect the mains plug from the
mains socket or switch off the
fuse in the fuse box. Close the
primary valve of the gas sup-
ply.
A
B
C
E
D
A)
Gas connection point (only one point
is applicable for appliance)
B)
Gasket
C)
Adjustable connection
D)
Natural Gas pipe holder
E)
LPG pipe holder
The appliance is set to default
gas, to change the setting
choose pipe holder from the list.
Always use the gasket sealing
13.5 Injectors replacement
1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the
type of gas you use.
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near
the gas supply pipe) with the one for
the new type of gas supply. You can
find this plate in the package sup-
plied with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
13.6 Adjustment of minimum
level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the
by-pass screw position (A). The by-
pass screw position (A) depends on
model.
• If you change from natural gas to liq-
uid gas, fully tighten the adjustment
screw in.
A