AEG 35146TG User Manual page 23

Table of Contents

Advertisement

Gas burners
Burner
Normal
power
kW
Auxiliary
1,00
burner
1,00
1,00
0,85
Semi-rap-
2,00
id burner
2,00
2,00
1,70
Triple
4,00
crown
burner
4,00
4,00
3,50
Oven
2,70
2,70
2,70
2,35
13.3 Gas Connection
Choose fixed connections or use a flexi-
ble pipe in stainless steel in compliance
with the regulation in force. If you use
flexible metallic pipes, be careful they
do not come in touch with mobile parts
or they are not squeezed.
Reduced
Type of
power
gas
kW
0,40
Natural
Gas G20
0,35
Natural
Gas G20
0,35
Butane
G30
0,31
Propane
G31
0,50
Natural
Gas G20
0,43
Natural
Gas G20
0,43
Butane
G30
0,38
Propane
G31
1,80
Natural
Gas G20
1,80
Natural
Gas G20
1,80
Butane
G30
1,60
Propane
G31
0,90
Natural
Gas G20
0,90
Natural
Gas G20
0,90
Butane
G30
0,78
Propane
G31
13.4 Flexible nonmetal pipes
connection
If it is possible to easily control the con-
nection in its full area, you can use a flex-
ible pipe. The flexible pipe must be
tightly attached by clamps.
ENGLISH
Pres-
Injector
sure
diame-
ter
mbar
mm
13
0,82
20
0,70
28 -
0,50
30
28 -
0,50
30
13
1,11
20
0,96
28 -
0,71
30
28 -
0,71
30
13
1,74
20
1,46
28 -
1,01
30
28 -
1,01
30
13
1,30
20
1,20
28 -
0,80
30
28 -
0,80
30
23
Usage
g/h
-
-
72,71
60,70
-
145,43
121,40
-
290,85
249,95
-
-
196,33
167,82