WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
!
BEFORE TROUBLE SHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or
loose switch wire connections in the switch
housing.
2. Fan sounds
1. Blades not attached to fan.
noisy.
2. Screws securing fan blade flanges to motor
are loose.
3. Wire connectors inside switch housing rattling.
4. Screws holding blades to flanges are loose.
5. Loose screws in motor housing.
3. Fan wobbles
1. Setscrew in motor coupling is not tightened
excessively.
securely.
2. Setscrew in the hanger ball/downrod assembly
is loose.
3. Screws securing fan blade flanges to
motor are loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box is
not securely fastened
6. Fan blades out of balance.
Trouble Shooting
PROBABLE CAUSE
1. Check main and branch circuit fuses or circuit breakers.
2. Check line power connections to fan and switch wire
connections in the switch housing.
WARNING: Make sure main power is turned off.
!
1. Attach blades to fan before operating.
2. Check to make sure the screws which attach the blade
flanges to the motor are tight.
3. Check to make sure wire connectors in switch housing are
not rattling against each other or against the interior wall of
the switch housing.
WARNING: Make sure main power is turned off.
!
4. Tighten screws securely.
5. Check to make sure all screws in motor housing are snug
(not over-tight)
1. Raise coupling cover and tighten setscrew securely.
2. Tighten the setscrew in the hanger ball/downrod assembly.
3. Check to be sure screws which attach the fan blade flanges
to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor. If flanges are seated
incorrectly, loosen the flange screws and retighten
according to Step 12 and Figure 6.
5. Tighten the hanger bracket screws to the outlet box, and/or
secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.