SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
SOUND
LOUD, INTERRUPTED*
FIRE ALARM
Touchpad & Ext. Sounder
LOUD, CONTINUOUS*
BURGLARY/AUDIBLE
Touchpad & Ext. Sounder
EMERGENCY ALARM
ONE SHORT BEEP
a. SYSTEM DISARM
(not repeated)
b. SYSTEM ARMING
Touchpad only
ATTEMPT WITH OPEN ZONE
c. BYPASS VERIFY
ONE BEEP every 40 sec.
a. SYSTEM IS IN TEST MODE
Touchpad only
b. LOW BATTERY AT A XMTR
TWO SHORT BEEPS
ARM AWAY
Touchpad only
THREE SHORT BEEPS
a. ARM STAY OR INSTANT
Touchpad only
b. ZONE OPENED WHILE SYS-
TEM IS IN CHIME MODE
c. ZONE OPENED WHILE SYS-
TEM IS IN TEST MODE
RAPID BEEPING
a. MEMORY OF ALARM
Touchpad only
b. EXT. SOUNDER WIRING
FAILURE
c. SYSTEM MAIN BATT. WEAK
d. TROUBLE
SLOW BEEPING
a. ENTRY DELAY WARNING
Touchpad only
b. EXIT DELAY ALERT
(if programmed)
*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is a steady ring.
(CUSTOM DISPLAY TOUCHPADS)
CAUSE
FIRE is displayed; description of zone in alarm is displayed.
ALARM is displayed; description of zone in alarm is also displayed..
Also see "Exit Alarm Warning Displays and Sounds" on page 20.
a. DISARMED/READY TO ARM is displayed. Green READY indicator is lit.
b. The number and description of the open protection zone is displayed. Green READY indicator is
not lit.
c. Numbers & descriptions of bypassed protection zones are displayed (one beep is heard for each
zone displayed). Subsequently, the following is displayed: DISARMED BYPASS/Ready to Arm
a. Identification of any opened zones will appear.
b. LO BAT displayed + zone # & transmitter description. OO & KYPD LO BAT for wireless touchpads.
ARMED AWAY/ALL SECURE is displayed. Red ARMED indicator is lit.
a. ARMED STAY or ARMED INSTANT is displayed. Red ARMED indicator is lit.
b. CHIME displayed. Pressing /READY [ ] key will display description of opened zone.
c. Description of open protection zone is displayed.
a. FIRE and/or ALARM is displayed; description of zone in alarm is displayed.
b. BELL FAILURE is displayed.
c. SYSTEM LO BAT displayed with no transmitter description.
d. CHECK displayed. Description of troubled protection zone is displayed.
a. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the delay time
without disarming causes alarm.
b. ARMED AWAY/you may exit now is displayed. Slow beeps change to fast beeps during
last 5 seconds of exit delay.
TOUCHPAD DISPLAY