Electrical Connection - Electrolux EOB6636 User Information

Built-in electric oven
Hide thumbs Also See for EOB6636:
Table of Contents

Advertisement

Electrical Connection

The oven is designed to be connected to 230-240V (50Hz) electricity sup-
ply.
The oven has an easily accessible terminal block which is marked as fol-
lows:
Letter L
Letter N
E
1
This oven must be earthed
The cable used to connect the oven to the electrical supply must comp ly to
the specifications given below.
For UK use only
Connection
via
• 13 A
socket outlet
• 13 A
spur box
• Cooker Control
Circuit
It is necessary that you install a double pole switch between the oven and
the electricity supply (mains), with a minimum gap of 3mm between the
switch contacts and of a type suitable for the required load in compliance
with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot
at any point reach a temperature of more than 50°C above the ambient tem-
perature.
Before the oven is connected, check that the main fuse and the domestic
installation can support the load; and that the power supply is properly
earthed.
The manufacturer desclaims any responsibility should these safety
measures not be carried out.
-
Live terminal
-
Neutral terminal
-
Earth terminal
Min. size
Cable/flex
2,5 mm
2,5 mm
Cable/flex
2
3 core butyl
insulated
2
PVC/PVC
twin and earth
type
13 A min.
15 A min.
20 A max.
Fuse
43