Yaesu FT-920 Operating Manual page 89

Hide thumbs Also See for FT-920:
Table of Contents

Advertisement

Note 1:
P1 = 01~7A: Memory Channel Number (Hex)
01~63: Memory Channels 1-01~1-99
64~6D: Memory Channels d-01~d-10
6E~78: Memory Channels C-01~C-11
79~7A: Memory Channels P-Lo~P-Hi
Note 2:
P1 = 01~7A: Memory Channel Number (Hex)
01~63: Memory Channels 1-01~1-99
64~6D: Memory Channels d-01~d-10
6E~78: Memory Channels C-01~C-11
79~7A: Memory Channels P-Lo~P-Hi
P2 = 00: Memory Store
P2 = 01: Memory Clear
P2 = 02: Memory Recall
Note 3:
P1 = 01~7A: Memory Channel Number (Hex)
01~63: Memory Channels 1-01~1-99
64~6D: Memory Channels d-01~d-10
6E~78: Memory Channels C-01~C-11
79~7A: Memory Channels P-Lo~P-Hi
Note 4:
P1 = 00: RX Clarifier Off
P1 = 01: RX Clarifier On
P1 = 80: TX Clarifier Off
P1 = 81: TX Clarifier On
P1 = FF: Set Clarifier
Note 5:
The frequency is converted to its BCD-coded components.
For example: to convert 14.256.78 MHz
P1 P2 P3 P4
5 Byte Block = 0A, 01, 42, 56, 78
Opcode
Note 6:
VFO-A Mode Parameters
VFO-B Mode Parameters
P1 = 00: LSB
P1 = 80: LSB
P1 = 01: USB
P1 = 81: USB
P1 = 02: CW-USB
P1 = 82: CW-USB
P1 = 03: CW-LSB
P1 = 83: CW-LSB
P1 = 04: AM
P1 = 84: AM
P1 = 05: AM
P1 = 85: AM
P1 = 06: FM
P1 = 86: FM
P1 = 07: FM-N
P1 = 87: FM-N
P1 = 08: DATA-LSB
P1 = 88: DATA-LSB
P1 = 09: DATA-LSB
P1 = 89: DATA-LSB
P1 = 0A: DATA-USB
P1 = 8A: DATA-USB
P1 = 0B: DATA-FM
P1 = 8B: DATA-FM
Note 7:
Status Update Data
P1 = 01: Memory Channel Number (1 byte)
P1 = 02: Current Operating Data for VFO/Memory (28 bytes)
P1 = 03: VFO-A and VFO-B Data (28 bytes)
P1 = 04: Memory Channel Data: (14 bytes)
P4 = 01~89 Memory Channel Number (used when P1 = 04)
01~63: Memory Channels 1-01~1-99
64~6D: Memory Channels d-01~d-10 (VFO-A)
6E~78: Memory Channels C-01~C-11
79~7A: Memory Channels P-Lo~P-Hi
7B~84: Memory Channels d-01~d-10 (VFO-B)
85~89: QMB Memories S-01~S-05
FT-920 Operating Manual
Notes to Opcode Command Chart
P2 = 00: Clarifier Offset (+)
P2 = FF: Clarifier Offset (-)
P3 = 00~09 (kHz)
P4 = 00~00 (100/10 Hz)
Note 8:
P3 = 00: Keyer Memory 0
P3 = 01: Keyer Memory 1
P3 = 02: Keyer Memory 2
P3 = 03: Keyer Memory 3
P3 = 04: "ID" Memory
P3 = 05: "Contest Number" Memory
P3 = 06: Keyer Memory Down
P3 = 07: Keyer Memory Up
P3 = 08: Keyer Memory Playback (no Tx)
P3 = 09: Write Memory
Note 9:
The frequency is converted to its BCD-coded components.
For example: to convert 14.256.78 MHz
P1 P2 P3 P4
5 Byte Block = 8A, 01, 42, 56, 78
Opcode
Note 10:
VFO-A Mode Parameters
VFO-B Mode Parameters
P1 = 00: Wide
P1 = 80: Wide
P1 = 01: Wide
P1 = 81: Wide
P1 = 02: Narrow
P1 = 82: Narrow
P1 = 03: Narrow
P1 = 83: Narrow
P1 = 04: Wide
P1 = 84: Wide
Note 11:
P1 = 00~28: Tone Encoder Frequency (Hex)
P2 = 00~27: Tone Decoder Frequency (Hex)
Note 12:
A digitized meter deflection indication is returned, with value be-
tween 0 and FFH; four sets of this data are sent, plus one pad-
ding byte (0F7H), as follows:
Met er Byt e
Met er Byt e
Met er Byt e
P1 = 00: S/PO, ALC, VOLT, AMP
P1 = 01: FWD, REV, SHIFT, PITCH
P1 = 02: Dummy byte, SQL, HPF, LPF
P1 = 03: NR, PROC, DISC, RMC
CTCSS Tone Data
P 1
Freq .
P 1
Freq .
P 2
(Hz )
P 2
(Hz )
00h
OFF
0Bh
94.8
01h
67.0
0Ch
97.4
02h
69.3
0Dh
100.0
03h
71.9
0Eh
103.5
04h
74.4
0Fh
107.2
05h
77.0
10h
110.9
06h
79.7
11h
114.8
07h
82.5
12h
118.8
08h
85.4
13h
123.0
09h
88.5
14h
127.3
0Ah
91.5
15h
131.8
Met er Byt e
F7H
P 1
Freq .
P 1
Freq .
P 2
(Hz )
P 2
(Hz )
16h
136.5
21h
203.5
17h
141.3
22h
210.7
18h
146.2
23h
218.1
19h
151.4
24h
225.7
1Ah
156.7
25h
233.6
1Bh
162.2
26h
241.8
1Ch
167.9
27h
250.3
1Dh
173.8
28h*
1750
1Eh
179.9
1Fh
186.2
20h
192.8
* 28h = P1 only