Download Print this page
Yaesu FT-950 - CAT OPERATION REFERENCE BOOK Reference

Yaesu FT-950 - CAT OPERATION REFERENCE BOOK Reference

Cat operation

Advertisement

Quick Links

CAT
O
( C
)
A
T
PERATION
OMPUTER
IDED
RANSCEIVER
FT-950
CAT O
PERATION
R
B
EFERENCE
OOK
FT-950 CAT O
R
B
PERATION
EFERENCE
OOK

Advertisement

loading
Need help?

Need help?

Do you have a question about the FT-950 - CAT OPERATION REFERENCE BOOK and is the answer not in the manual?

Questions and answers

Summary of Contents for Yaesu FT-950 - CAT OPERATION REFERENCE BOOK

  • Page 1 PERATION OMPUTER IDED RANSCEIVER FT-950 CAT O PERATION EFERENCE FT-950 CAT O PERATION EFERENCE...
  • Page 2 PERATION OMPUTER IDED RANSCEIVER CAT J VERVIEW The CAT (Computer Aided Transceiver) System in the FT-950 transceiver provides control of frequency, VFO, memory, and other settings such as dual-channel memo- ries and diversity reception using an external personal computer. This allows multiple control operations to be fully automated as single mouse clicks or keystroke op- erations on the computer keyboard.
  • Page 3 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND Parameters A computer control command is composed of an alpha- betical command, various parameters, and the terminator Parameters are used to specify information necessary to that signals the end of the control command. implement the desired command. Example: Set the VFO-A frequency to 14.250000 MHz.
  • Page 4 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND OMMAND UNCTION OMMAND UNCTION VFO-A TO VFO-B METER SW ANTENNA TUNER CONTROL MEMORY WRITE AF GAIN MOX SET AUTO INFORMATION NARROW VFO-A TO MEMORY CHANNEL NOISE BLANKER ANTENNA NUMBER NOISE BLANKER LEVEL AUTO NOTCH NOISE REDUCTION BAND DOWN OPPOSITE BAND INFORMATION...
  • Page 5 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES VFO-A TO VFO-B Read Answer A A A A A C C C C C ANTENNA TUNER CONTROL P1 0: Fixed P3 0: Tuner “OFF” P2 0: Fixed 1: Tuner “ON” P1 P2 P3 2: Tuning Start Read Answer...
  • Page 6 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES MANUAL NOTCH P1 0: Fixed P3 When P2=0 P2 0: Manual NOTCH “ON/OFF” 000: OFF P1 P2 P3 P3 P3 1: Manual NOTCH LEVEL 001: ON Read When P2=1 P1 P2 001 - 300 (NOTCH Frequency : x 10 Hz ) Answer P1 P2 P3 P3 P3 BAND SELECT...
  • Page 7 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES CTCSS P1 0: Fixed P2 0: CTCSS “OFF” P1 P2 1: CTCSS ENC/DEC “ON” Read 2: CTCSS ENC “ON” Answer P1 P2 D D D D D A A A A A DIMMER P1 00 - 15: Backlight Brightness Level P2 00: Fixed P1 P1 P2 P2...
  • Page 8 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES MENU P1 : 001-118 (MENU Number) P2 : Parameter (See Table 2 and Table 3) P1 P1 P1 P2 P2 Read P1 P1 P1 Answer P1 P1 P1 P2 P2 ABLE FUNCTION 0020 ~ 4000 msec ( 20 msec/step ) AGC FAST DELAY TIME 0020 ~ 4000 msec ( 20 msec/step ) AGC MID DELAY TIME...
  • Page 9 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES ABLE FUNCTION SPECTRUM SCOPE SCAN START FREQUENCY ( 1.8 MHz ) 01800 ~ 01999 (1.800 MHz ~ 1.999 MHz) SPECTRUM SCOPE SCAN START FREQUENCY ( 3.5 MHz ) 03500 ~ 03999 (3.500 MHz ~ 3.999 MHz) SPECTRUM SCOPE SCAN START FREQUENCY ( 5.0 MHz ) 05250 ~ 05499 (5.250 MHz ~ 5.499 MHz) SPECTRUM SCOPE SCAN START FREQUENCY ( 7.0 MHz )
  • Page 10 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES F F F F F A A A A A FREQUENCY VFO-A P1 0030000 - 56000000 (Hz) P1 P1 P1 P1 P1 P1 P1 P1 Read Answer P1 P1 P1 P1 P1 P1 P1 P1 FREQUENCY VFO-B P1 0030000 - 56000000 (Hz) P1 P1 P1 P1 P1 P1 P1 P1...
  • Page 11 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES IF IF INFORMATION P1 000-117 (Memory Channel) P2 VFO-A Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Clarifier Offset: 0000 - 9999 (Hz) Read P4 0: RX CLAR “OFF” 1: RX CLAR “ON”...
  • Page 12 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES LOAD MESSEGE P1 0: Fixed P2 0: DVS-6 (Recording Stop) P1 P2 1: DVS-6 (CH “1” Recording Start/Stop) Read 2: DVS-6 (CH “2” Recording Start/Stop) 3: DVS-6 (CH “3” Recording Start/Stop) : This command does not activates Answer 4: DVS-6 (CH “4”...
  • Page 13 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES METER SW P1 0: COMP 1: ALC 3: SWR Read 4: ID 5: VDD Answer MEMORY CHANNEL WRITE P1 Memory Channel Number P2 Memory Channel Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift P1 P1 P1 P2 P2 P2 P2 P2 Clarifier Offset: 0000 - 9999 (Hz) P4 0: RX CLAR “OFF”...
  • Page 14 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES OFFSET (REPEATER SHIFT) P1 0: Fixed P2 0: Simplex P1 P2 1: Plus Shift Read 2: Minus Shift : This command can be activated only with an FM mode. Answer P1 P2 P P P P P A A A A A PRE-AMP (IPO) P1 0: Fixed P2 0: IPO...
  • Page 15 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES QUICK SPLIT Read Answer RF ATTENUATOR P1 0: Fixed P2 0: OFF P1 P2 1: 6 dB Read 2: 12 dB 3: 18 dB Answer P1 P2 R R R R R C C C C C CLAR CLEAR Read Answer...
  • Page 16 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES R R R R R O O O O O ROTATOR P1 0: OFF 1: Counter Clockwise 2: Clockwise Read 3: SPEED 1 % DOWN 4: SPEED 1 % UP Answer P2 DIRECTION (0 - 450) P3 SPEED (0 - 100 %) P1 P2 P2 P2 P3 P3 P3 RADIO STATUS...
  • Page 17 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES SQUELCLH LEVEL P1 0: Fixed P2 000 - 255 P1 P2 P2 P2 Read Answer P1 P2 P2 P2 SWAP VFO Read Answer P1 0: TXW “OFF” 1: TXW “ON” Read Answer TX SET P1 0: RADIO TX “OFF”...
  • Page 18 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES VOX DELAY TIME P1 0030 - 3000 mS (10 mS/step) P1 P1 P1 P1 Read Answer P1 P1 P1 P1 VRF FILTER P1 0: Fixed P4 0 - 9 (Step) P2 0: OFF P5 000 - 255 P1 P2 P3 P4 1: ON...
  • Page 19 PERATION OMPUTER IDED RANSCEIVER FT-950 CAT O Page 18 PERATION EFERENCE...
  • Page 20 PERATION OMPUTER IDED RANSCEIVER Copyright 2007 VERTEX STANDARD CO., LTD. All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. FT-950 CAT O PERATION EFERENCE...

This manual is also suitable for: